CCD linearity measurement by incremental binning (Conference Presentation)

S. Kaye, Roger M. Smith, P. Mao, Timothee Greffe
{"title":"CCD linearity measurement by incremental binning (Conference Presentation)","authors":"S. Kaye, Roger M. Smith, P. Mao, Timothee Greffe","doi":"10.1117/12.2314251","DOIUrl":null,"url":null,"abstract":"The traditional method for measuring CCD non-linearity using constant flux and variable exposure time is compared to a faster and potentially more accurate method that requires just two exposures at low intensity. Signal is varied by parallel-binning a successively greater number of lines. The binned image is compared to a conventional image with identical illumination, co-added digitally in the same pattern. This method requires no shutter calibration and is insensitive to illumination drift or charge transfer inefficiency. With some additional software effort, it can be arranged to tolerate illumination non-uniformity. We present data obtained by both methods for the 64 CD231-C6 outputs and discuss automated performance optimization. We find that the widely held assumption that non-linearity only affects high signals is incorrect when optimizing for minimum gain change over the full signal range, in which case slope increases with signal initially, then peaks in the mid-range before dropping again.","PeriodicalId":359588,"journal":{"name":"High Energy, Optical, and Infrared Detectors for Astronomy VIII","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"High Energy, Optical, and Infrared Detectors for Astronomy VIII","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2314251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The traditional method for measuring CCD non-linearity using constant flux and variable exposure time is compared to a faster and potentially more accurate method that requires just two exposures at low intensity. Signal is varied by parallel-binning a successively greater number of lines. The binned image is compared to a conventional image with identical illumination, co-added digitally in the same pattern. This method requires no shutter calibration and is insensitive to illumination drift or charge transfer inefficiency. With some additional software effort, it can be arranged to tolerate illumination non-uniformity. We present data obtained by both methods for the 64 CD231-C6 outputs and discuss automated performance optimization. We find that the widely held assumption that non-linearity only affects high signals is incorrect when optimizing for minimum gain change over the full signal range, in which case slope increases with signal initially, then peaks in the mid-range before dropping again.
用增量分束法测量CCD线性度(会议报告)
使用恒定通量和可变曝光时间测量CCD非线性的传统方法与只需在低强度下进行两次曝光的更快且可能更准确的方法进行了比较。信号的变化是通过连续更大数量的线并行并行。将该图像与具有相同照明的传统图像进行比较,并以相同的模式进行数字叠加。该方法不需要快门校准,对照明漂移或电荷转移效率低下不敏感。通过一些额外的软件工作,它可以被安排为容忍光照不均匀性。我们给出了64个CD231-C6输出的两种方法获得的数据,并讨论了自动性能优化。我们发现,在整个信号范围内优化最小增益变化时,普遍认为非线性只影响高信号的假设是不正确的,在这种情况下,斜率最初随着信号增加,然后在中间范围达到峰值,然后再次下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信