Induced voltage behavior on pipelines due to HV AC interference under broken OHEW

M. Nassereddine, J. Rizk, A. Hellany, M. Nagrial
{"title":"Induced voltage behavior on pipelines due to HV AC interference under broken OHEW","authors":"M. Nassereddine, J. Rizk, A. Hellany, M. Nagrial","doi":"10.1109/AUPEC.2013.6725375","DOIUrl":null,"url":null,"abstract":"High voltage infrastructure upgrade is expending due to the growth in populations. To save on easement cost and to reduce the environmental impact of these projects, HV transmission lines occupy the same easement as pipelines in many cases. This joint easement introduces the AC interference between transmission lines and pipelines. The induced voltage can reach a limit which will jeopardize the human safety. The cited research studies the induced voltage under the presence of the OHEW using the shielding factor. The works under this paper study the induced voltage using the OHEW section current along with the superposition theorem. The simulations are compared to the existing research methods. The case study along with the theoretical study discusses the impact of a broken OHEW on the induced voltage using the existing research methods and the proposed method.","PeriodicalId":121040,"journal":{"name":"2013 Australasian Universities Power Engineering Conference (AUPEC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Australasian Universities Power Engineering Conference (AUPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AUPEC.2013.6725375","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

High voltage infrastructure upgrade is expending due to the growth in populations. To save on easement cost and to reduce the environmental impact of these projects, HV transmission lines occupy the same easement as pipelines in many cases. This joint easement introduces the AC interference between transmission lines and pipelines. The induced voltage can reach a limit which will jeopardize the human safety. The cited research studies the induced voltage under the presence of the OHEW using the shielding factor. The works under this paper study the induced voltage using the OHEW section current along with the superposition theorem. The simulations are compared to the existing research methods. The case study along with the theoretical study discusses the impact of a broken OHEW on the induced voltage using the existing research methods and the proposed method.
高压交流干扰在断流条件下对管道的感应电压行为
由于人口的增长,高压基础设施的升级正在增加。为了节省地役权成本,减少这些项目对环境的影响,在许多情况下,高压输电线路与管道占用相同的地役权。这种联合减震器引入了输电线路和管道之间的交流干扰。感应电压会达到一定的极限,危及人身安全。引用的研究利用屏蔽系数研究了OHEW存在下的感应电压。本文利用OHEW截面电流和叠加定理对感应电压进行了研究。仿真结果与现有的研究方法进行了比较。结合理论研究和实例研究,分别运用现有的研究方法和所提出的方法讨论了OHEW断裂对感应电压的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信