{"title":"Field measurements, modeling, and analysis of power system harmonics caused by industrial customers","authors":"Jesus Jativa-Ibarra, Gabriela Navarro-Mendez, F. Quilumba, Weijen Lee","doi":"10.1109/IAS.2014.6978488","DOIUrl":null,"url":null,"abstract":"Due to problems caused by non-linear loads in a power system, a harmonic technical analysis on the hydroelectric generating units Illuchi 1 and 2 of the Electric Utility Company of Cotopaxi Province ELEPCO S.A., Ecuador, is performed in this project by means of industrial analyzers as well as software simulation. The analysis starts from harmonic distortion measurements on the generating plants and El Calvario substation. Then, simulations are performed including non-linear loads characterized as current sources in the east zone of the studied system by using a harmonic power flow to determine the industrial load causing the current fluctuations. The maximum values of THD are in the order of 5.4% and 3% in Illuchi 1 and 2, respectively, that are above the recommended values of IEEE Std. 519-1992. Based on these results and determined the cause, filters for 5th and 7th harmonic according to the IEEE Std. 1531-2003 are designed.","PeriodicalId":446068,"journal":{"name":"2014 IEEE Industry Application Society Annual Meeting","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Industry Application Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2014.6978488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Due to problems caused by non-linear loads in a power system, a harmonic technical analysis on the hydroelectric generating units Illuchi 1 and 2 of the Electric Utility Company of Cotopaxi Province ELEPCO S.A., Ecuador, is performed in this project by means of industrial analyzers as well as software simulation. The analysis starts from harmonic distortion measurements on the generating plants and El Calvario substation. Then, simulations are performed including non-linear loads characterized as current sources in the east zone of the studied system by using a harmonic power flow to determine the industrial load causing the current fluctuations. The maximum values of THD are in the order of 5.4% and 3% in Illuchi 1 and 2, respectively, that are above the recommended values of IEEE Std. 519-1992. Based on these results and determined the cause, filters for 5th and 7th harmonic according to the IEEE Std. 1531-2003 are designed.
现场测量,建模和分析电力系统谐波引起的工业客户
针对电力系统中非线性负荷引起的问题,本项目采用工业分析仪和软件仿真相结合的方法,对厄瓜多尔科托帕西省电力公司ELEPCO s.a.的Illuchi 1和2号水力发电机组进行了谐波技术分析。本文从发电厂和El Calvario变电站的谐波畸变测量入手进行分析。在此基础上,利用谐波潮流对系统东段以电流源为特征的非线性负荷进行了仿真,确定了引起电流波动的工业负荷。图1和图2中THD的最大值分别为5.4%和3%,均高于IEEE Std. 519-1992的推荐值。在此基础上,根据IEEE标准1531-2003设计了5次谐波和7次谐波滤波器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信