Simple ELISA Methods to Estimate Neutralizing Antibody Titers to SARS-CoV-2: IgG Quantification, the Avidity Index, and the Surrogate Virus Neutralization Test

Victor Manuylov, I. Dolzhikova, A. Kudryashova, B. Cherepovich, A. Kovyrshina, A. Iliukhina, O. Kharchenko, M. Semashko, A. Tkachuk, V. Gushchin, O. Borisova
{"title":"Simple ELISA Methods to Estimate Neutralizing Antibody Titers to SARS-CoV-2: IgG Quantification, the Avidity Index, and the Surrogate Virus Neutralization Test","authors":"Victor Manuylov, I. Dolzhikova, A. Kudryashova, B. Cherepovich, A. Kovyrshina, A. Iliukhina, O. Kharchenko, M. Semashko, A. Tkachuk, V. Gushchin, O. Borisova","doi":"10.26502/ami.93650088","DOIUrl":null,"url":null,"abstract":"Antibody the Surrogate Neutralization Test. Abstract A total of 104 sera sampled from vaccinated (“Sputnik V”, Russia) volunteers were tested in parallel to determine different markers of humoral immunity against SARS-CoV-2. Testing was conducted using the neutralizing antibodies titer (NtAb) in the virus neutralization assay (VNA), the IgG to RBD in the quantitative ELISA (BAU/ml), the avidity index (AI) of the IgG to RBD (also in ELISA), and the titers of “neutralizing antibodies” which can block an interaction between human ACE2 and the viral RBD proteins in a competitive ELISA surrogate virus neutralization test (sVNT). The correlation coefficients between the quantitative results in the tried ELISA assays and the “true” NtAb titers in the VNA were high, with the following values: r=0.86 for BAU/ml (95% confidence interval, CI: 0.80-0.91, p<0.0001); 0.54 for the AI (95% CI: 0,38-0,67, p<0.0001); and 0.84 for the sVNT titer (95% CI:0.79-0.90). Additionally, it was found that the multiplicative index of BAU/ml × AI (which corresponds to the concentration of the high-affinity fraction of the total IgG to the RBD) gives a maximum correlation to the NtAb titers (r=0.89, 95% CI: 0.84-0.92, p<0.0001). The sensitivity and specificity, respectively, of the tested ELISA assays in recognizing the supposedly protective NtAb titer of ≥1:160 were the following: for the BAU/ml – 87.7±8% and 97.4±5%; for the (BAU/ml ×","PeriodicalId":222617,"journal":{"name":"Archives of Microbiology &amp; Immunology","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Microbiology &amp; Immunology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26502/ami.93650088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Antibody the Surrogate Neutralization Test. Abstract A total of 104 sera sampled from vaccinated (“Sputnik V”, Russia) volunteers were tested in parallel to determine different markers of humoral immunity against SARS-CoV-2. Testing was conducted using the neutralizing antibodies titer (NtAb) in the virus neutralization assay (VNA), the IgG to RBD in the quantitative ELISA (BAU/ml), the avidity index (AI) of the IgG to RBD (also in ELISA), and the titers of “neutralizing antibodies” which can block an interaction between human ACE2 and the viral RBD proteins in a competitive ELISA surrogate virus neutralization test (sVNT). The correlation coefficients between the quantitative results in the tried ELISA assays and the “true” NtAb titers in the VNA were high, with the following values: r=0.86 for BAU/ml (95% confidence interval, CI: 0.80-0.91, p<0.0001); 0.54 for the AI (95% CI: 0,38-0,67, p<0.0001); and 0.84 for the sVNT titer (95% CI:0.79-0.90). Additionally, it was found that the multiplicative index of BAU/ml × AI (which corresponds to the concentration of the high-affinity fraction of the total IgG to the RBD) gives a maximum correlation to the NtAb titers (r=0.89, 95% CI: 0.84-0.92, p<0.0001). The sensitivity and specificity, respectively, of the tested ELISA assays in recognizing the supposedly protective NtAb titer of ≥1:160 were the following: for the BAU/ml – 87.7±8% and 97.4±5%; for the (BAU/ml ×
简易ELISA法测定SARS-CoV-2中和抗体滴度:IgG定量、亲和度指数和替代病毒中和试验
抗体替代物中和试验。本研究对104例接种过“Sputnik V”疫苗的志愿者血清进行平行检测,以确定其对SARS-CoV-2的不同体液免疫标志物。采用病毒中和试验(VNA)中的中和抗体滴度(NtAb)、定量ELISA中的抗RBD IgG (BAU/ml)、ELISA中抗RBD IgG的亲和度指数(AI)以及竞争性ELISA替代病毒中和试验(sVNT)中阻断人ACE2与病毒RBD蛋白相互作用的“中和抗体”滴度进行检测。所试ELISA法定量结果与VNA中NtAb“真实”滴度的相关系数较高,BAU/ml的r=0.86(95%置信区间,CI: 0.80 ~ 0.91, p<0.0001);人工智能为0.54 (95% CI: 0,38-0,67, p<0.0001);sVNT滴度为0.84 (95% CI:0.79-0.90)。此外,我们还发现,BAU/ml × AI的乘法指数(对应于RBD中总IgG高亲和力部分的浓度)与NtAb滴度的相关性最大(r=0.89, 95% CI: 0.84-0.92, p<0.0001)。所测ELISA法对NtAb滴度≥1:160的保护性检测的敏感性和特异性分别为:BAU/ml - 87.7±8%和97.4±5%;为(BAU/ml ×
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信