Compact, MR compatible SiPM small animal PET DOI detector

R. Chil, G. Konstantinou, M. Desco, J. Vaquero
{"title":"Compact, MR compatible SiPM small animal PET DOI detector","authors":"R. Chil, G. Konstantinou, M. Desco, J. Vaquero","doi":"10.1109/NSSMIC.2016.8069413","DOIUrl":null,"url":null,"abstract":"We introduce a compact preclinical PET detector that combines the output from 64 SiPM channels, forming an 8×8 matrix of pixels capable of efficiently encoding event position, with good energy and time resolution, as well as depth of interaction information. The scintillator matrices used to characterize the detector are a 16×16 matrix comprised of 1.3×1.3×12mm3 LYSO crystals, and a 1.3×1.3×15mm3 GSO/LYSO phoswhich. Preliminary results regarding spatial resolution show that the detector has a resolvability index of 0.25, an energy resolution below 14% for the 511KeV peak and a good separation between the two different phoswich crystal layers. Due to the compactness and MR compatibility of this detector it is proposed as a candidate to substitute those based on the R8900 PS-PMT in a full ring system that could be inserted into the MR bore of a preclinical PET-MR imager.","PeriodicalId":184587,"journal":{"name":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2016.8069413","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

We introduce a compact preclinical PET detector that combines the output from 64 SiPM channels, forming an 8×8 matrix of pixels capable of efficiently encoding event position, with good energy and time resolution, as well as depth of interaction information. The scintillator matrices used to characterize the detector are a 16×16 matrix comprised of 1.3×1.3×12mm3 LYSO crystals, and a 1.3×1.3×15mm3 GSO/LYSO phoswhich. Preliminary results regarding spatial resolution show that the detector has a resolvability index of 0.25, an energy resolution below 14% for the 511KeV peak and a good separation between the two different phoswich crystal layers. Due to the compactness and MR compatibility of this detector it is proposed as a candidate to substitute those based on the R8900 PS-PMT in a full ring system that could be inserted into the MR bore of a preclinical PET-MR imager.
紧凑,MR兼容SiPM小动物PET DOI检测器
我们介绍了一种紧凑的临床前PET检测器,它结合了64个SiPM通道的输出,形成了一个8×8像素矩阵,能够有效地编码事件位置,具有良好的能量和时间分辨率,以及交互信息的深度。用于表征探测器的闪烁体矩阵是由1.3×1.3×12mm3 LYSO晶体组成的16×16矩阵和1.3×1.3×15mm3 GSO/LYSO光斑。在空间分辨率方面的初步结果表明,探测器的分辨指数为0.25,511KeV峰的能量分辨率低于14%,两种不同的光子晶体层之间的分离良好。由于该检测器的紧凑性和MR兼容性,建议将其作为基于R8900 PS-PMT的全环系统的候选替代品,该系统可以插入临床前PET-MR成像仪的MR孔中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信