{"title":"An AC power amplifier for testing instrument transformer test equipment","authors":"E. Mohns, S. Fricke, F. Pauling","doi":"10.1109/CPEM.2016.7540559","DOIUrl":null,"url":null,"abstract":"This paper describes the design and setup of analogue power amplifiers for generating calibration signals for test equipment for instrument transformers. Two amplifiers have been set up for a rating of 600 VA and 70 VA, respectively. The 600 VA version is used for testing standard burdens, while the other one is used as a source for a calibrator for testing test sets for conventional and non-conventional current or voltage transformers. The amplifiers offer the possibility to switch between a voltage mode and a current mode. The bandwidth of the amplifiers covers the range from 16.7 Hz to at least 3 kHz. Different ranges between 80 V to 280 V in the voltage mode, and 2 A to 10 A in the current mode are realized with a transformer-coupled output stage. The gain accuracy is in the order of 1 %, while the stability is better than 0.01 %. The smaller amplifier will be used to set up future measurement systems in the EMRP project \"Non-conventional voltage and current sensors for future power grids\".","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2016.7540559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
This paper describes the design and setup of analogue power amplifiers for generating calibration signals for test equipment for instrument transformers. Two amplifiers have been set up for a rating of 600 VA and 70 VA, respectively. The 600 VA version is used for testing standard burdens, while the other one is used as a source for a calibrator for testing test sets for conventional and non-conventional current or voltage transformers. The amplifiers offer the possibility to switch between a voltage mode and a current mode. The bandwidth of the amplifiers covers the range from 16.7 Hz to at least 3 kHz. Different ranges between 80 V to 280 V in the voltage mode, and 2 A to 10 A in the current mode are realized with a transformer-coupled output stage. The gain accuracy is in the order of 1 %, while the stability is better than 0.01 %. The smaller amplifier will be used to set up future measurement systems in the EMRP project "Non-conventional voltage and current sensors for future power grids".