S. Wagner, N. H. Rasmussen, P. Ahrendt, T. Toftegaard, O. Bertelsen
{"title":"Context classification during blood pressure self-measurement using the sensor seat and the audio classification device","authors":"S. Wagner, N. H. Rasmussen, P. Ahrendt, T. Toftegaard, O. Bertelsen","doi":"10.4108/ICST.PERVASIVEHEALTH.2012.248700","DOIUrl":null,"url":null,"abstract":"Blood pressure self-measurement (BPSM) requires the patient to follow a range of recommendations. Patients must remain silent during measurements, be seated correctly with back support and legs uncrossed, and must have rested at least 5 minutes prior to taking the measurement. Current blood pressure (BP) devices cannot verify whether the patient has followed these recommendations or not. As a result, the data quality of BP measurements could be biased. We present a proof-of-concept demonstration prototype that uses audio context classification for detecting speech during the measurement process, as well as a sensor seat for measuring patient posture and activity before and during the BPSM process.","PeriodicalId":119950,"journal":{"name":"2012 6th International Conference on Pervasive Computing Technologies for Healthcare (PervasiveHealth) and Workshops","volume":"101 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 6th International Conference on Pervasive Computing Technologies for Healthcare (PervasiveHealth) and Workshops","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4108/ICST.PERVASIVEHEALTH.2012.248700","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Blood pressure self-measurement (BPSM) requires the patient to follow a range of recommendations. Patients must remain silent during measurements, be seated correctly with back support and legs uncrossed, and must have rested at least 5 minutes prior to taking the measurement. Current blood pressure (BP) devices cannot verify whether the patient has followed these recommendations or not. As a result, the data quality of BP measurements could be biased. We present a proof-of-concept demonstration prototype that uses audio context classification for detecting speech during the measurement process, as well as a sensor seat for measuring patient posture and activity before and during the BPSM process.