The variability of delivered dose of aerosols with the same respirable concentration but different size distributions.

N. Esmen, D. Johnson, G. Agron
{"title":"The variability of delivered dose of aerosols with the same respirable concentration but different size distributions.","authors":"N. Esmen, D. Johnson, G. Agron","doi":"10.1093/ANNHYG/MEF046","DOIUrl":null,"url":null,"abstract":"The influences of aerosol size distribution and breath tidal volume on respirable dose estimates were examined for mouth breathing using the ACGIH/ISO/CEN criterion for respirable-equivalent aerosols. Actual tissue doses predicted from a set of pulmonary empirical deposition equations, the Heyder-Rudolf equations, were compared with deposition assumed to occur under the penetration-based respirable dust sampling criterion. Deposition estimate errors ranged from approximately 1/10- to 10-fold, with aerosol mass median aerodynamic equivalent diameter and geometric standard deviation as well as tidal volume each showing a substantial influence under appropriate conditions. These findings demonstrate that reliance on respirable aerosol sampling data obtained with devices performing on a penetration-based sampling criterion may lead to erroneous dose-response relationships in exposure standard development as well as exposure misclassification errors during epidemiological studies. A more reliable dose estimate would be obtained using devices with collection efficiency performance closely matching the alveolar deposition prediction curves of Heyder and Rudolf. We believe that if it is not currently required, the development of a deposition-based aerosol sampling methodology will soon be required for the determination and quantification of inhaled aerosol-induced adverse health effects.","PeriodicalId":342592,"journal":{"name":"The Annals of occupational hygiene","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Annals of occupational hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ANNHYG/MEF046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

The influences of aerosol size distribution and breath tidal volume on respirable dose estimates were examined for mouth breathing using the ACGIH/ISO/CEN criterion for respirable-equivalent aerosols. Actual tissue doses predicted from a set of pulmonary empirical deposition equations, the Heyder-Rudolf equations, were compared with deposition assumed to occur under the penetration-based respirable dust sampling criterion. Deposition estimate errors ranged from approximately 1/10- to 10-fold, with aerosol mass median aerodynamic equivalent diameter and geometric standard deviation as well as tidal volume each showing a substantial influence under appropriate conditions. These findings demonstrate that reliance on respirable aerosol sampling data obtained with devices performing on a penetration-based sampling criterion may lead to erroneous dose-response relationships in exposure standard development as well as exposure misclassification errors during epidemiological studies. A more reliable dose estimate would be obtained using devices with collection efficiency performance closely matching the alveolar deposition prediction curves of Heyder and Rudolf. We believe that if it is not currently required, the development of a deposition-based aerosol sampling methodology will soon be required for the determination and quantification of inhaled aerosol-induced adverse health effects.
可吸入浓度相同但粒径分布不同的气溶胶输送剂量的变异性。
采用ACGIH/ISO/CEN呼吸当量气溶胶标准,研究了气溶胶粒径分布和呼吸潮气量对口腔呼吸可吸入剂量估计的影响。根据一组肺经验沉积方程(Heyder-Rudolf方程)预测的实际组织剂量与基于穿透性呼吸性粉尘采样标准假设发生的沉积进行了比较。沉积估计误差约为1/10至10倍,在适当条件下,气溶胶质量中位数气动等效直径和几何标准偏差以及潮汐量均显示出重大影响。这些发现表明,依赖基于渗透取样标准的设备获得的可吸入性气溶胶取样数据可能导致暴露标准制定中的剂量-反应关系错误,以及流行病学研究中的暴露误分类错误。使用收集效率性能与Heyder和Rudolf的肺泡沉积预测曲线密切匹配的设备,可以获得更可靠的剂量估计。我们认为,即使目前不需要,也将很快需要开发一种基于沉积的气溶胶采样方法,以确定和量化吸入气溶胶引起的不利健康影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信