The Assessment of Time and Storage Environment Effects on Dimensional Changes of Two Types of Acrylic Resin Post Patterns GC and Reliance

Amin Khaleghi, Malihe Taghizadeh, M. Hormozi
{"title":"The Assessment of Time and Storage Environment Effects on Dimensional Changes of Two Types of Acrylic Resin Post Patterns GC and Reliance","authors":"Amin Khaleghi, Malihe Taghizadeh, M. Hormozi","doi":"10.18502/ijds.v17i2.6875","DOIUrl":null,"url":null,"abstract":"Introduction: The purpose of this study was to investigate and compare the dimensional changes in the acrylic patterns that were stored in the different times and conditions of storage. \nMaterials& Methods: In this experimental study The sample number was 28 in 4 groups. The mixed paste of acrylic samples were placed inside a metal mold and after setting time with the slightest of deformations it was removed. Using this method 28 samples were prepared for each material. The diameters of samples were then measured immediately using a digital caliper with a precision of 0.01 mm. The samples were then divided into four quadruple groups and stored at 22° C room temperature, 22° Cat water, Dry 4° C environment and 4° C water. The dimensions of the four groups were measured at intervals of 1, 8, 24, and 48 hours after polymerization and being removed from the metal molds. The ANOVA test was used for data analysis (p value = 0.05). \nResults: The findings of the current study showed that the dimensional changes of Duralay and GC acrylic resins at both 4 and 22° C in dry and water environments are decreasing over time (p value < 0.001). This study indicated that the contraction rate of two types of acrylic resins, Duralay and GC, at two temperatures of 4 and 22° C, and dry and humid conditions and at various times were not different. \nConclusion: Dimensional changes in of the two types of acrylic resin, Duralay and GC, During the lapse, the procedure is going to be decreased but have not seen any statistical difference between these type of acrylic resin in environment storage.","PeriodicalId":221865,"journal":{"name":"Journal of Isfahan Dental School","volume":"389 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Isfahan Dental School","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/ijds.v17i2.6875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The purpose of this study was to investigate and compare the dimensional changes in the acrylic patterns that were stored in the different times and conditions of storage. Materials& Methods: In this experimental study The sample number was 28 in 4 groups. The mixed paste of acrylic samples were placed inside a metal mold and after setting time with the slightest of deformations it was removed. Using this method 28 samples were prepared for each material. The diameters of samples were then measured immediately using a digital caliper with a precision of 0.01 mm. The samples were then divided into four quadruple groups and stored at 22° C room temperature, 22° Cat water, Dry 4° C environment and 4° C water. The dimensions of the four groups were measured at intervals of 1, 8, 24, and 48 hours after polymerization and being removed from the metal molds. The ANOVA test was used for data analysis (p value = 0.05). Results: The findings of the current study showed that the dimensional changes of Duralay and GC acrylic resins at both 4 and 22° C in dry and water environments are decreasing over time (p value < 0.001). This study indicated that the contraction rate of two types of acrylic resins, Duralay and GC, at two temperatures of 4 and 22° C, and dry and humid conditions and at various times were not different. Conclusion: Dimensional changes in of the two types of acrylic resin, Duralay and GC, During the lapse, the procedure is going to be decreased but have not seen any statistical difference between these type of acrylic resin in environment storage.
时间和贮存环境对两种丙烯酸树脂桩型尺寸变化的影响
前言:本研究的目的是调查和比较亚克力图案在不同的储存时间和条件下的尺寸变化。材料与方法:本实验共分为4组,样本数28例。将亚克力样品混合后的浆料放入金属模具中,待凝固一段时间后,变形最小即可取出。用这种方法对每种材料制备了28个样品。然后立即使用精度为0.01 mm的数字卡尺测量样品的直径。将样品分为4组,分别保存在22°C室温、22°C清水、4°C干燥环境和4°C清水中。在聚合并从金属模具中取出后的1、8、24和48小时间隔测量四组的尺寸。资料分析采用方差分析(ANOVA)检验(p值= 0.05)。结果:本研究结果表明,在干燥和水环境下,Duralay和GC丙烯酸树脂在4°C和22°C下的尺寸变化随时间的推移而减小(p值< 0.001)。本研究表明,Duralay和GC两种丙烯酸树脂在4℃和22℃两种温度、干湿条件和不同时间下的收缩率没有差异。结论:Duralay和GC两种丙烯酸树脂的尺寸变化,在使用过程中,工序会减少,但两种丙烯酸树脂在环境储存方面没有统计学差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信