Non Intrusive Network Impedance Estimation with State of the Art PLC Modems

Davide Righini, A. Tonello
{"title":"Non Intrusive Network Impedance Estimation with State of the Art PLC Modems","authors":"Davide Righini, A. Tonello","doi":"10.1109/ISPLC48789.2020.9115400","DOIUrl":null,"url":null,"abstract":"The knowledge of the Power Line (PL) network impedance is relevant to improve the performance of the communication system and enable smart grid monitoring and diagnostics. This paper introduces a new method to estimate the PL grid impedance exploiting only voltage measurements and changes of the load at the receiver side of the Power Line Communication Modem (PLM). The proposed estimation technique is called Non Intrusive (NI) because does not require signals to be injected at the measurement port. But signals originated from a remote node are exploited for the impedance estimation. The exploitation of PLMs not only as communication devices but also to sense the Power Line Network (PLN) parameters, will promote new applications in the domain of PL diagnostics and allow better PL grid monitoring. The method was evaluated through simulations and real measurements. The proposed approach applies to both single and multi-conductor technologies at different frequency bands.","PeriodicalId":403692,"journal":{"name":"2020 IEEE International Symposium on Power Line Communications and its Applications (ISPLC)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Symposium on Power Line Communications and its Applications (ISPLC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPLC48789.2020.9115400","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The knowledge of the Power Line (PL) network impedance is relevant to improve the performance of the communication system and enable smart grid monitoring and diagnostics. This paper introduces a new method to estimate the PL grid impedance exploiting only voltage measurements and changes of the load at the receiver side of the Power Line Communication Modem (PLM). The proposed estimation technique is called Non Intrusive (NI) because does not require signals to be injected at the measurement port. But signals originated from a remote node are exploited for the impedance estimation. The exploitation of PLMs not only as communication devices but also to sense the Power Line Network (PLN) parameters, will promote new applications in the domain of PL diagnostics and allow better PL grid monitoring. The method was evaluated through simulations and real measurements. The proposed approach applies to both single and multi-conductor technologies at different frequency bands.
非侵入式网络阻抗估计与最先进的PLC调制解调器
电力线(PL)网络阻抗的知识与提高通信系统的性能和实现智能电网监控和诊断相关。本文介绍了一种仅利用电力线通信调制解调器(PLM)接收端电压测量和负载变化来估计PLM栅极阻抗的新方法。所提出的估计技术被称为非侵入式(NI),因为不需要在测量端口注入信号。但是来自远程节点的信号被用于阻抗估计。利用plm不仅作为通信设备,而且还可以感知电力线网络(PLN)参数,将促进PL诊断领域的新应用,并允许更好的PL电网监测。通过仿真和实际测量对该方法进行了验证。该方法适用于不同频段的单导体和多导体技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信