{"title":"Measurements of Low-energy X-rays with a Detector Using a Plastic Scintillator and an MPPC","authors":"S. Kishimoto, M. Sakamaki, K. Amemiya","doi":"10.7566/jpscp.27.012003","DOIUrl":null,"url":null,"abstract":"An MPPC (Multi-Pixel Photon Counter) has some advantages of a low-voltage operation and easily making a multi-element type detector, when comparing with a photomultiplier tube. We tried to detect soft X-rays of less than 6 keV with a scintillation detector using an MPPC. The detector consists of a plastic scintillator (Pilot-U, 5 mm in diameter and 1 mm thick) and an MPPC (Hamamatsu Photonics, S13360-6642, 3×3 mm2, pixel size: 25 μm, without a resin window). We measured pulse-height spectra using a charge-sensitive preamplifier, cooled down to −10°C. The detector could clearly distinguish 6 keV X-rays from noise signals. We also measured time spectra of X-ray pulse structure of 2-ns intervals in the multibunch operating mode of the Photon Factory ring. A time resolution (Full width of half-maximum) of 0.51±0.06 ns was obtained at a bias voltage of +60.0 V and at −10°C, using a fast amplifier having a gain of 100.","PeriodicalId":228570,"journal":{"name":"Proceedings of the 5th International Workshop on New Photon-Detectors (PD18)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 5th International Workshop on New Photon-Detectors (PD18)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7566/jpscp.27.012003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
An MPPC (Multi-Pixel Photon Counter) has some advantages of a low-voltage operation and easily making a multi-element type detector, when comparing with a photomultiplier tube. We tried to detect soft X-rays of less than 6 keV with a scintillation detector using an MPPC. The detector consists of a plastic scintillator (Pilot-U, 5 mm in diameter and 1 mm thick) and an MPPC (Hamamatsu Photonics, S13360-6642, 3×3 mm2, pixel size: 25 μm, without a resin window). We measured pulse-height spectra using a charge-sensitive preamplifier, cooled down to −10°C. The detector could clearly distinguish 6 keV X-rays from noise signals. We also measured time spectra of X-ray pulse structure of 2-ns intervals in the multibunch operating mode of the Photon Factory ring. A time resolution (Full width of half-maximum) of 0.51±0.06 ns was obtained at a bias voltage of +60.0 V and at −10°C, using a fast amplifier having a gain of 100.