Measurements of Low-energy X-rays with a Detector Using a Plastic Scintillator and an MPPC

S. Kishimoto, M. Sakamaki, K. Amemiya
{"title":"Measurements of Low-energy X-rays with a Detector Using a Plastic Scintillator and an MPPC","authors":"S. Kishimoto, M. Sakamaki, K. Amemiya","doi":"10.7566/jpscp.27.012003","DOIUrl":null,"url":null,"abstract":"An MPPC (Multi-Pixel Photon Counter) has some advantages of a low-voltage operation and easily making a multi-element type detector, when comparing with a photomultiplier tube. We tried to detect soft X-rays of less than 6 keV with a scintillation detector using an MPPC. The detector consists of a plastic scintillator (Pilot-U, 5 mm in diameter and 1 mm thick) and an MPPC (Hamamatsu Photonics, S13360-6642, 3×3 mm2, pixel size: 25 μm, without a resin window). We measured pulse-height spectra using a charge-sensitive preamplifier, cooled down to −10°C. The detector could clearly distinguish 6 keV X-rays from noise signals. We also measured time spectra of X-ray pulse structure of 2-ns intervals in the multibunch operating mode of the Photon Factory ring. A time resolution (Full width of half-maximum) of 0.51±0.06 ns was obtained at a bias voltage of +60.0 V and at −10°C, using a fast amplifier having a gain of 100.","PeriodicalId":228570,"journal":{"name":"Proceedings of the 5th International Workshop on New Photon-Detectors (PD18)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 5th International Workshop on New Photon-Detectors (PD18)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7566/jpscp.27.012003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An MPPC (Multi-Pixel Photon Counter) has some advantages of a low-voltage operation and easily making a multi-element type detector, when comparing with a photomultiplier tube. We tried to detect soft X-rays of less than 6 keV with a scintillation detector using an MPPC. The detector consists of a plastic scintillator (Pilot-U, 5 mm in diameter and 1 mm thick) and an MPPC (Hamamatsu Photonics, S13360-6642, 3×3 mm2, pixel size: 25 μm, without a resin window). We measured pulse-height spectra using a charge-sensitive preamplifier, cooled down to −10°C. The detector could clearly distinguish 6 keV X-rays from noise signals. We also measured time spectra of X-ray pulse structure of 2-ns intervals in the multibunch operating mode of the Photon Factory ring. A time resolution (Full width of half-maximum) of 0.51±0.06 ns was obtained at a bias voltage of +60.0 V and at −10°C, using a fast amplifier having a gain of 100.
用塑料闪烁体和MPPC探测器测量低能x射线
与光电倍增管相比,MPPC(多像素光子计数器)具有工作电压低、易于制作多元件型探测器等优点。我们尝试用MPPC闪烁探测器探测小于6 keV的软x射线。该探测器由一个塑料闪烁体(Pilot-U,直径5mm,厚1mm)和一个MPPC (Hamamatsu Photonics, S13360-6642, 3×3 mm2,像素尺寸:25 μm,无树脂窗)组成。我们使用电荷敏感前置放大器测量脉冲高度光谱,冷却至- 10°C。探测器能从噪声信号中清楚地分辨出6种keV x射线。我们还测量了光子工厂环在多束工作模式下2-ns间隔的x射线脉冲结构的时间谱。使用增益为100的快速放大器,在+60.0 V的偏置电压和- 10°C下,获得了0.51±0.06 ns的时间分辨率(半最大值全宽度)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信