{"title":"Fault-tolerant cascaded multi-level inverter with improved output quality","authors":"K. Thantirige, S. K. Panda, A. Rathore, S. Mukherjee, M. Zagrodnik, A. Gupta","doi":"10.1109/ICSET.2016.7811805","DOIUrl":null,"url":null,"abstract":"This paper presents an enhanced reconfiguration method for the cascaded H-bridge inverter (CHBI) that maintains high quality of the output voltage waveforms. This method is based on controlled shifting of the system neutral point together with the phase-shifted pulse-width modulation (PS-PWM) scheme. During fault conditions, if the carrier signals are not properly adjusted in the healthy working power cells, then the output line-to-line voltages get distorted with high harmonic content. With the proposed method, carrier signals' frequency and phases are modified according to the available operative cells within the faulty phases. The proposed implementation is modeled in the MATLAB/Simulink for a 7-level CHBI under various cell fault conditions. Simulation test results confirm the performance enhancement attained with the proposed method. This reconfiguration method can easily be realized since the changes of the PS-PWM strategy can be implemented in software, without additional hardware requirements.","PeriodicalId":164446,"journal":{"name":"2016 IEEE International Conference on Sustainable Energy Technologies (ICSET)","volume":"267 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Sustainable Energy Technologies (ICSET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSET.2016.7811805","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents an enhanced reconfiguration method for the cascaded H-bridge inverter (CHBI) that maintains high quality of the output voltage waveforms. This method is based on controlled shifting of the system neutral point together with the phase-shifted pulse-width modulation (PS-PWM) scheme. During fault conditions, if the carrier signals are not properly adjusted in the healthy working power cells, then the output line-to-line voltages get distorted with high harmonic content. With the proposed method, carrier signals' frequency and phases are modified according to the available operative cells within the faulty phases. The proposed implementation is modeled in the MATLAB/Simulink for a 7-level CHBI under various cell fault conditions. Simulation test results confirm the performance enhancement attained with the proposed method. This reconfiguration method can easily be realized since the changes of the PS-PWM strategy can be implemented in software, without additional hardware requirements.
提高输出质量的容错级联多级逆变器
本文提出了一种改进的级联h桥逆变器重构方法,该方法能保持输出电压波形的高质量。该方法基于系统中性点的可控移位和相移脉宽调制(PS-PWM)方案。在故障状态下,如果在正常工作的动力电池中对载波信号调整不当,则输出线对线电压失真,谐波含量高。利用该方法,根据故障相位内可用的工作单元来修改载波信号的频率和相位。在MATLAB/Simulink中对各种单元故障条件下的7级CHBI进行了建模。仿真测试结果证实了该方法的性能增强效果。这种重新配置方法很容易实现,因为PS-PWM策略的改变可以在软件中实现,而不需要额外的硬件要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信