{"title":"Integration of a Low-Cost Three-Axis Sensor for Robot Force Control","authors":"Shuyang Chen, Jianren Wang, P. Kazanzides","doi":"10.1109/IRC.2018.00052","DOIUrl":null,"url":null,"abstract":"Many robot systems incorporate six-axis force/torque sensors to enable compliant interaction with the environment, even when a lower-cost three-axis sensor may be sufficient. One challenge is that a three-axis sensor may measure a coupling of the applied forces and torques; these can be decoupled with an appropriate calibration and with assumed knowledge of the location of the applied force. In this paper, we develop the method and open source software to calibrate a commercially-available three-axis sensor and verify its performance in static tests with known weights and in dynamic tests by comparison to an accurate six-axis sensor. Mean errors in static tests are less than 5% and experiments demonstrate that the sensor can be used to control the contact force applied by a robot-held ultrasound probe.","PeriodicalId":416113,"journal":{"name":"2018 Second IEEE International Conference on Robotic Computing (IRC)","volume":"160 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Second IEEE International Conference on Robotic Computing (IRC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRC.2018.00052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Many robot systems incorporate six-axis force/torque sensors to enable compliant interaction with the environment, even when a lower-cost three-axis sensor may be sufficient. One challenge is that a three-axis sensor may measure a coupling of the applied forces and torques; these can be decoupled with an appropriate calibration and with assumed knowledge of the location of the applied force. In this paper, we develop the method and open source software to calibrate a commercially-available three-axis sensor and verify its performance in static tests with known weights and in dynamic tests by comparison to an accurate six-axis sensor. Mean errors in static tests are less than 5% and experiments demonstrate that the sensor can be used to control the contact force applied by a robot-held ultrasound probe.
集成低成本三轴传感器的机器人力控制
许多机器人系统都包含六轴力/扭矩传感器,以实现与环境的兼容交互,即使在成本较低的三轴传感器可能足够的情况下。其中一个挑战是,三轴传感器可能会测量施加的力和扭矩的耦合;这些可以通过适当的校准和假定的施加力位置知识来解耦。在本文中,我们开发了一种方法和开源软件来校准市售的三轴传感器,并通过与精确的六轴传感器进行比较,验证其在已知重量的静态测试和动态测试中的性能。静态测试的平均误差小于5%,实验表明该传感器可用于控制机器人手持超声探头施加的接触力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信