Device Application to Improve Patient Safety and Image Quality during Chest CT Examination of Unconscious Patients

Seong-Min Kim, Yeun-ju Kim, S. Choi, K. Lee
{"title":"Device Application to Improve Patient Safety and Image Quality during Chest CT Examination of Unconscious Patients","authors":"Seong-Min Kim, Yeun-ju Kim, S. Choi, K. Lee","doi":"10.31320/jksct.2023.25.1.11","DOIUrl":null,"url":null,"abstract":"This study was to analyze the effect on patient safety and image quality improvement by lowering the arm and applying a self-made device during chest CT examinations of unconscious patients. From April 1 to September 30, 2022, 78 patients (male: 42, female: 36, mean age: 67 years old) among intensive care unit patients who underwent chest CT scan were retrospectively reviewed. The patients were classified into three positions as follows: both arms raised (A position), both arms straight out using the self-made device (B position), and both arms straight out to the side (C position). For radiation dose comparison, dose length product (DLP) values were measured and compared to each other. For image quality evaluation, image noise, signal to noise ratio (SNR), contrast to noise ratio (CNR), and contrast to dose ratio (CNRDR) values were compared, and qualitative evaluation was also performed. The average DLP value of the B position was significantly lower than that of the C position, and it was relatively higher than that of the A position, but there was no significant difference statistically.(p=0.051) In the quantitative evaluation, it was evaluated that the B position maintains a quality quite similar to that of the A position despite the lowering of the both arms. In addition, in the qualitative evaluation, an average score was obtained between A and C. In conclusion, it was confirmed that the use of the self-made device for rapid and safe chest CT examination of unconscious patients is useful in improving patient dose and image quality.","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Society of Computed Tomographic Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31320/jksct.2023.25.1.11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study was to analyze the effect on patient safety and image quality improvement by lowering the arm and applying a self-made device during chest CT examinations of unconscious patients. From April 1 to September 30, 2022, 78 patients (male: 42, female: 36, mean age: 67 years old) among intensive care unit patients who underwent chest CT scan were retrospectively reviewed. The patients were classified into three positions as follows: both arms raised (A position), both arms straight out using the self-made device (B position), and both arms straight out to the side (C position). For radiation dose comparison, dose length product (DLP) values were measured and compared to each other. For image quality evaluation, image noise, signal to noise ratio (SNR), contrast to noise ratio (CNR), and contrast to dose ratio (CNRDR) values were compared, and qualitative evaluation was also performed. The average DLP value of the B position was significantly lower than that of the C position, and it was relatively higher than that of the A position, but there was no significant difference statistically.(p=0.051) In the quantitative evaluation, it was evaluated that the B position maintains a quality quite similar to that of the A position despite the lowering of the both arms. In addition, in the qualitative evaluation, an average score was obtained between A and C. In conclusion, it was confirmed that the use of the self-made device for rapid and safe chest CT examination of unconscious patients is useful in improving patient dose and image quality.
提高昏迷患者胸部CT检查患者安全和图像质量的设备应用
本研究旨在分析在对无意识患者进行胸部CT检查时,降低手臂并应用自制装置对患者安全及图像质量改善的影响。回顾性分析2022年4月1日至9月30日期间重症监护病房行胸部CT扫描患者78例(男42例,女36例,平均年龄67岁)。将患者分为三种体位:双臂抬起(A位)、使用自制器械双臂伸直(B位)、双臂伸直向侧(C位)。对于辐射剂量比较,测量剂量长度积(DLP)值并相互比较。对图像质量进行评价,比较图像噪声、信噪比(SNR)、噪声比(CNR)、剂量比(CNRDR)值,并进行定性评价。B位的平均DLP值明显低于C位,相对高于A位,但在统计学上无显著差异(p=0.051)在定量评价中,评价B位在双臂降低的情况下仍保持了与A位相当的质量。定性评价中,A ~ c的平均得分为A ~ c。综上所述,使用自制装置对昏迷患者进行快速、安全的胸部CT检查,有助于提高患者的剂量和图像质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信