FACILITY FOR CALIBRATION OF PHOTOMETERS FOR TEMPORAL LIGHT MODULATION

P. Dekker, A.L. van Bloois
{"title":"FACILITY FOR CALIBRATION OF PHOTOMETERS FOR TEMPORAL LIGHT MODULATION","authors":"P. Dekker, A.L. van Bloois","doi":"10.25039/x48.2021.op27","DOIUrl":null,"url":null,"abstract":"We developed a facility for calibration of TLM (temporal light modulation) photometers. The facility is based on a laser-fed reference source, of which the radiance can be modulated with an acousto-optic modulator (AOM). A system of photodiodes, amplifiers, and an analog-to-digital converter (ADC) is used to sample the temporally modulated radiance of the source. With the facility a TLM photometer was calibrated for display contrast ratio RMS (root mean square) with an absolute combined standard uncertainty of 0,037 %. In addition, the facility has been characterised with the aim of measuring flicker and stroboscopic effect, considering the Ecodesign ‘Single Lighting Regulation’. The frequency response of the facility shows to be sufficient to accommodate measurements of flicker and the stroboscopic effect.","PeriodicalId":363368,"journal":{"name":"Proceedings of the Conference CIE 2021","volume":"613 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Conference CIE 2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25039/x48.2021.op27","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We developed a facility for calibration of TLM (temporal light modulation) photometers. The facility is based on a laser-fed reference source, of which the radiance can be modulated with an acousto-optic modulator (AOM). A system of photodiodes, amplifiers, and an analog-to-digital converter (ADC) is used to sample the temporally modulated radiance of the source. With the facility a TLM photometer was calibrated for display contrast ratio RMS (root mean square) with an absolute combined standard uncertainty of 0,037 %. In addition, the facility has been characterised with the aim of measuring flicker and stroboscopic effect, considering the Ecodesign ‘Single Lighting Regulation’. The frequency response of the facility shows to be sufficient to accommodate measurements of flicker and the stroboscopic effect.
校正光度计以作时间光调制的设备
我们开发了一种用于校准TLM(时间光调制)光度计的设备。该设施基于激光馈电参考源,其辐射可以用声光调制器(AOM)调制。一个由光电二极管、放大器和模数转换器(ADC)组成的系统被用来对光源的暂时调制辐射进行采样。使用该设备对TLM光度计进行了显示对比度RMS(均方根)的校准,绝对组合标准不确定度为0,037%。此外,考虑到Ecodesign的“单一照明法规”,该设施的特点是测量闪烁和频闪效应。该设备的频率响应显示足以适应闪烁和频闪效应的测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信