Image Processing for X-ray Calibration Phantom

Nutthanan Wanluk, C. Pintavirooj, T. Treebupachatsakul
{"title":"Image Processing for X-ray Calibration Phantom","authors":"Nutthanan Wanluk, C. Pintavirooj, T. Treebupachatsakul","doi":"10.1109/BMEICON.2018.8609973","DOIUrl":null,"url":null,"abstract":"Medical device calibration is the process of ensuring that there is accuracy before using. X-ray imaging device is one of the high-risk medical devices that must be calibrated. The calibration process required these values to be measured; center ray, focal object distance (FOD), resolution, and linearity of the imaging system. But the devices used to measure each of these are expensive. In this paper, a design of the x-ray calibration phantom that is affordable and yet effective is presented. An aluminum rectangular phantom consists of a center ray calibration unit, focal object distance (FOD) calibration unit and Linearity calibration unit. The x-ray image of all the phantom unit can be analyzed automatically by using the digital image processing.","PeriodicalId":232271,"journal":{"name":"2018 11th Biomedical Engineering International Conference (BMEiCON)","volume":"221 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 11th Biomedical Engineering International Conference (BMEiCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEICON.2018.8609973","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Medical device calibration is the process of ensuring that there is accuracy before using. X-ray imaging device is one of the high-risk medical devices that must be calibrated. The calibration process required these values to be measured; center ray, focal object distance (FOD), resolution, and linearity of the imaging system. But the devices used to measure each of these are expensive. In this paper, a design of the x-ray calibration phantom that is affordable and yet effective is presented. An aluminum rectangular phantom consists of a center ray calibration unit, focal object distance (FOD) calibration unit and Linearity calibration unit. The x-ray image of all the phantom unit can be analyzed automatically by using the digital image processing.
x射线校准幻影的图像处理
医疗器械校准是在使用前确保其准确性的过程。x射线成像设备是必须进行校准的高风险医疗设备之一。校准过程需要测量这些值;成像系统的中心射线、焦距(FOD)、分辨率和线性度。但是用于测量这些的设备都很昂贵。本文提出了一种经济有效的x射线校准模体设计方案。铝制矩形模体由中心射线标定单元、焦距标定单元和线性标定单元组成。采用数字图像处理技术,可对所有虚体单元的x射线图像进行自动分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信