{"title":"Fundamental limitations imposed by RHP poles and zeros in SISO systems","authors":"Byung-Moon Kwon, H. Ryu, Dae-woo Kim, O. Kwon","doi":"10.1109/SICE.2001.977827","DOIUrl":null,"url":null,"abstract":"Establishes limitations on the impulse response of an LTI system based on the open-loop poles and zeros located in the convergence region of the closed-loop transfer function. Using the definition of Laplace transform, it is shown that time-domain integral constraints have to be satisfied by the impulse response of the SISO stable system and that the maximum value of impulse response has some lower bounds according to the achievable settling time of the system. Also, it shows the reason why it is very difficult to control the system with open-loop RHP (right half plane) poles or zeros using the unity-feedback scheme in the view of small impulse response. These results can be used to determine a priori whether desired design specifications axe achievable or not.","PeriodicalId":415046,"journal":{"name":"SICE 2001. Proceedings of the 40th SICE Annual Conference. International Session Papers (IEEE Cat. No.01TH8603)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICE 2001. Proceedings of the 40th SICE Annual Conference. International Session Papers (IEEE Cat. No.01TH8603)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2001.977827","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Establishes limitations on the impulse response of an LTI system based on the open-loop poles and zeros located in the convergence region of the closed-loop transfer function. Using the definition of Laplace transform, it is shown that time-domain integral constraints have to be satisfied by the impulse response of the SISO stable system and that the maximum value of impulse response has some lower bounds according to the achievable settling time of the system. Also, it shows the reason why it is very difficult to control the system with open-loop RHP (right half plane) poles or zeros using the unity-feedback scheme in the view of small impulse response. These results can be used to determine a priori whether desired design specifications axe achievable or not.
在SISO系统中RHP极点和零点所施加的基本限制
基于闭环传递函数收敛区域的开环极点和零点,建立了对LTI系统脉冲响应的限制。利用拉普拉斯变换的定义,证明了SISO稳定系统的脉冲响应必须满足时域积分约束,并且根据系统可达到的稳定时间,脉冲响应的最大值有一定的下界。同时,从脉冲响应小的角度分析了单位反馈方案难以控制开环右半平面极点或零点的原因。这些结果可以用来先验地确定所期望的设计规格是否可以实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信