Yaqub Mahnashi, K. Qureshi, A. Al-Shehri, Hussein Attia
{"title":"Microwave-Based Technique for Measuring Glucose Levels in Aqueous Solutions","authors":"Yaqub Mahnashi, K. Qureshi, A. Al-Shehri, Hussein Attia","doi":"10.1109/IMAS55807.2023.10066913","DOIUrl":null,"url":null,"abstract":"This study describes a non-invasive method for measuring the glucose level in aqueous solutions using a microwave-based system. The test sample (i.e., glucose-water solution) is subjected to a microwave signal. Two RF microstrip patch antennas manufactured using an FR-4 substrate and resonating at 5.7 GHz are used to create the suggested glucose sensor. The glucose-water solution is placed between the two antennas. An electronic conditioning circuit (i.e., analog readout circuit) is used to condition the received signal. A novel method to measure the amount of glucose is to observe the variation in the DC output voltage on the receiver side. Utilizing glucose-water testing samples, the technique is experimentally validated. For a concentration range of 0–5000 mg/dL, the experimental findings support the relationship between glucose concentration and the DC output voltage.","PeriodicalId":246624,"journal":{"name":"2023 International Microwave and Antenna Symposium (IMAS)","volume":"342 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 International Microwave and Antenna Symposium (IMAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMAS55807.2023.10066913","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This study describes a non-invasive method for measuring the glucose level in aqueous solutions using a microwave-based system. The test sample (i.e., glucose-water solution) is subjected to a microwave signal. Two RF microstrip patch antennas manufactured using an FR-4 substrate and resonating at 5.7 GHz are used to create the suggested glucose sensor. The glucose-water solution is placed between the two antennas. An electronic conditioning circuit (i.e., analog readout circuit) is used to condition the received signal. A novel method to measure the amount of glucose is to observe the variation in the DC output voltage on the receiver side. Utilizing glucose-water testing samples, the technique is experimentally validated. For a concentration range of 0–5000 mg/dL, the experimental findings support the relationship between glucose concentration and the DC output voltage.