Characteristic of Independent Two AC Motor Drives Fed by a Five-Leg Inverter

K. Oka, Y. Ohama, H. Kubota, I. Miki, K. Matsuse
{"title":"Characteristic of Independent Two AC Motor Drives Fed by a Five-Leg Inverter","authors":"K. Oka, Y. Ohama, H. Kubota, I. Miki, K. Matsuse","doi":"10.1109/IAS.2009.5324838","DOIUrl":null,"url":null,"abstract":"This paper presents the experimental test results of the independent vector control characteristics of two three- phase induction motors (IMs) and two three-phase permanent magnet synchronous motors (PMSMs) fed by a five-leg inverter (FLI). To drive two motors (IMs or PMSMs) independently, the system connected one motor to one three-phase voltage source inverter (three-VSI) is generally used and is required two three- VSIs. Therefore, twelve and ten-switching devices are necessary in the three-VSIs and FLI respectively. Finally, the FLI can decrease two-switches and will be expected for saving space and reduction of inverter losses. Experimental results are verified for the independent driving characteristics in two motors with the FLI.","PeriodicalId":178685,"journal":{"name":"2009 IEEE Industry Applications Society Annual Meeting","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2009.5324838","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

This paper presents the experimental test results of the independent vector control characteristics of two three- phase induction motors (IMs) and two three-phase permanent magnet synchronous motors (PMSMs) fed by a five-leg inverter (FLI). To drive two motors (IMs or PMSMs) independently, the system connected one motor to one three-phase voltage source inverter (three-VSI) is generally used and is required two three- VSIs. Therefore, twelve and ten-switching devices are necessary in the three-VSIs and FLI respectively. Finally, the FLI can decrease two-switches and will be expected for saving space and reduction of inverter losses. Experimental results are verified for the independent driving characteristics in two motors with the FLI.
由五腿逆变器供电的独立两个交流电机驱动器的特性
本文介绍了由五腿逆变器(FLI)供电的两台三相感应电动机(IMs)和两台三相永磁同步电动机(pmms)的独立矢量控制特性的实验测试结果。为了独立驱动两台电机(IMs或pmms),一般采用将一台电机连接到一台三相电压源逆变器(3 - vsi)的系统,需要两台3 - vsi。因此,在三个vsi和FLI中分别需要十二个和十个开关器件。最后,FLI可以减少两个开关,预计将节省空间和减少逆变器损耗。实验结果验证了具有FLI的两台电机的独立驱动特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信