Real free space antenna factors for validating completely absorber lined chambers?

D.J. Groot Boerle, F. Leferink
{"title":"Real free space antenna factors for validating completely absorber lined chambers?","authors":"D.J. Groot Boerle, F. Leferink","doi":"10.1109/ISEMC.1996.561219","DOIUrl":null,"url":null,"abstract":"The validation of a completely absorber lined chamber (CALC) turned out to be difficult. The first attempt was made with antennas calibrated on an open area test site (OATS). In this case a correction factor was necessary, this factor is related to the ground reflection and thus to the antennas. The validation started with determining the real free space antenna factors (AF/sub FS/). These real free space antenna factors were used for new site attenuation measurements in the CALC. The goal has been to validate the CALC by means of practical measurements. As a result the CALC can meet the normalized site attenuation (NSA) requirements. Because of near field effects and mutual coupling a minor problem area below 80 MHz remains, this problem was not dealt with. In our opinion the CALC should replace the OATS as the reference site. In conclusion, a CALC is the best test site for compliance testing for both immunity and emission, and all radiated EMC-measurements should be normalized to free space.","PeriodicalId":296175,"journal":{"name":"Proceedings of Symposium on Electromagnetic Compatibility","volume":"138 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1996.561219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

The validation of a completely absorber lined chamber (CALC) turned out to be difficult. The first attempt was made with antennas calibrated on an open area test site (OATS). In this case a correction factor was necessary, this factor is related to the ground reflection and thus to the antennas. The validation started with determining the real free space antenna factors (AF/sub FS/). These real free space antenna factors were used for new site attenuation measurements in the CALC. The goal has been to validate the CALC by means of practical measurements. As a result the CALC can meet the normalized site attenuation (NSA) requirements. Because of near field effects and mutual coupling a minor problem area below 80 MHz remains, this problem was not dealt with. In our opinion the CALC should replace the OATS as the reference site. In conclusion, a CALC is the best test site for compliance testing for both immunity and emission, and all radiated EMC-measurements should be normalized to free space.
真实自由空间天线系数验证完全吸收器衬里腔室?
完全吸收器内衬腔(CALC)的验证是困难的。第一次尝试是在一个开放区域试验场(OATS)校准天线。在这种情况下,校正因子是必要的,这个因子与地面反射有关,因此与天线有关。验证从确定实际自由空间天线因子(AF/sub / FS/)开始。这些真实自由空间天线因子被用于CALC中的新站点衰减测量,目的是通过实际测量来验证CALC。因此,CALC可以满足归一化站点衰减(NSA)的要求。由于近场效应和相互耦合,80mhz以下的小问题区域仍然存在,因此没有处理这个问题。在我们看来,CALC应该取代OATS作为参考站点。综上所述,CALC是抗扰度和发射符合性测试的最佳测试场所,所有辐射emc测量都应归一化到自由空间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信