{"title":"Motor Thermal Protection by Continuous Monitoring of Winding Resistance","authors":"D. Paice","doi":"10.1109/TIECI.1980.351666","DOIUrl":null,"url":null,"abstract":"Simple practical techniques which sense ac line current afford protection of motor windings for many applications. A more complete protection system is described which continuously monitors average winding resistance and hence temperature by means of an easily applied dc injection technique. No additional motor connections are required.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"241 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1980-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"69","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Industrial Electronics and Control Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIECI.1980.351666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 69
Abstract
Simple practical techniques which sense ac line current afford protection of motor windings for many applications. A more complete protection system is described which continuously monitors average winding resistance and hence temperature by means of an easily applied dc injection technique. No additional motor connections are required.