Kaiyuan Pang, Yizheng Wang, F. Wen, I. Palu, Zeng Yang, Minghui Chen, Hongwei Zhao, Huiyu Shang
{"title":"A Resilience-Enhancing System Restoration Method Considering Voltage Balance","authors":"Kaiyuan Pang, Yizheng Wang, F. Wen, I. Palu, Zeng Yang, Minghui Chen, Hongwei Zhao, Huiyu Shang","doi":"10.1109/PESGM41954.2020.9281725","DOIUrl":null,"url":null,"abstract":"Nowadays, power system resilience presents higher requirements for restorative self-healing strategies considering both restoring and operating performances. This paper sheds light on a resilience-enhancing restoration strategy considering voltage balance, which is formulated as a two-stage mixed integer linear programming (MILP) problem. An improved non-black-start (NBS) generator start-up model is presented in the first stage, and used to determine the restoration sequence of generators, power lines, and loads with maximum restored load capacity. Besides, a linear power flow model with transmission loss ignored is employed in the second stage, with an aim of attaining most balanced post-restoration voltage by readjusting the power outputs from generators. The IEEE 30-bus power system is used to demonstrate the correctness and effectiveness of the proposed two-stage strategy.","PeriodicalId":106476,"journal":{"name":"2020 IEEE Power & Energy Society General Meeting (PESGM)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Power & Energy Society General Meeting (PESGM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM41954.2020.9281725","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Nowadays, power system resilience presents higher requirements for restorative self-healing strategies considering both restoring and operating performances. This paper sheds light on a resilience-enhancing restoration strategy considering voltage balance, which is formulated as a two-stage mixed integer linear programming (MILP) problem. An improved non-black-start (NBS) generator start-up model is presented in the first stage, and used to determine the restoration sequence of generators, power lines, and loads with maximum restored load capacity. Besides, a linear power flow model with transmission loss ignored is employed in the second stage, with an aim of attaining most balanced post-restoration voltage by readjusting the power outputs from generators. The IEEE 30-bus power system is used to demonstrate the correctness and effectiveness of the proposed two-stage strategy.