{"title":"Mathematical Modeling of Transient Processes of the Automatic Control System of Water Level in the Steam Generator","authors":"Siddikov Isamiddin Xakimovich, Umurzakova Dilnoza Maxamadjonovna","doi":"10.13189/UJME.2019.070401","DOIUrl":null,"url":null,"abstract":"The methodology of creation of automatic control system (ACS) of water level in the steam generator is developed. The mathematical model of checking its working capacity is developed, which allows establishing the maximum deviations of water level without carrying out full-scale tests, without adjusting the settings of tripping actuation according to the water level in the drum. The foreign methods of PID-regulator adjustment in the cascade system of automatic water level control in the boiler drum are considered, on the basis of which an invariant cascade system of automatic control is proposed. The invariant Cascade-System of Automatic Control (CSAC) of water level in a boiler drum is offered. Simulation results of the invariant cascade-system of automatic control in comparison with CSAC, configured with best foreign method, showed a significant improvement in the quality of regulation in all the major disturbing influences. The results can be used in the development of adaptive control systems and other thermal power devices.","PeriodicalId":275027,"journal":{"name":"Universal Journal of Mechanical Engineering","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Universal Journal of Mechanical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13189/UJME.2019.070401","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23
Abstract
The methodology of creation of automatic control system (ACS) of water level in the steam generator is developed. The mathematical model of checking its working capacity is developed, which allows establishing the maximum deviations of water level without carrying out full-scale tests, without adjusting the settings of tripping actuation according to the water level in the drum. The foreign methods of PID-regulator adjustment in the cascade system of automatic water level control in the boiler drum are considered, on the basis of which an invariant cascade system of automatic control is proposed. The invariant Cascade-System of Automatic Control (CSAC) of water level in a boiler drum is offered. Simulation results of the invariant cascade-system of automatic control in comparison with CSAC, configured with best foreign method, showed a significant improvement in the quality of regulation in all the major disturbing influences. The results can be used in the development of adaptive control systems and other thermal power devices.