TAHANAN LATERAL SAMBUNGAN GESER GANDA KAYU KARET FJLB – PELAT BESI DENGAN ALAT SAMBUNG BAUT

Sherly Octavia, A. Awaludin, Urwatul Wusqo
{"title":"TAHANAN LATERAL SAMBUNGAN GESER GANDA KAYU KARET FJLB – PELAT BESI DENGAN ALAT SAMBUNG BAUT","authors":"Sherly Octavia, A. Awaludin, Urwatul Wusqo","doi":"10.20961/jrrs.v6i1.62337","DOIUrl":null,"url":null,"abstract":"Timber Instant House (RIKA) is one of the recommended earthquake-resistant houses during the post-disaster reconstruction project. However, in practice, this instant house faces problems with timber material availability. One solution that can be offered is to use Finger Joint Laminated Board (FJLB) material as a structural component. For the design of earthquake-resistant buildings, one of the components that need to be reviewed carefully is the connection component. In this study, the lateral resistance of the FJLB connection with steel will be reviewed. The connection tool used is a bolt. The joints are tested using a monotonic load in the direction parallel to the grain and perpendicular to the grain. The test results on 12 test objects with the ASTM D-5764-97a standard were then compared with the results of manual calculations using the European Yield Model (EYM) theory listed in Eurocode 5. From the test, the average value of the lateral resistance per bolt was 18.63 kN (parallel to the grain) and 15.22 kN (perpendicular to the grain). The ratio between the value of lateral resistance of the test results and theoretical using EYM is close to a value of 1, where most of the connection failure modes from the test results are close to the theoretical connection failure modes. Thus, it can be concluded that applying the EYM theory to the FJLB connection with steel using a bolt connection is still relevant and gives results that are quite close to the test results.","PeriodicalId":448424,"journal":{"name":"Jurnal Riset Rekayasa Sipil","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Riset Rekayasa Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20961/jrrs.v6i1.62337","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Timber Instant House (RIKA) is one of the recommended earthquake-resistant houses during the post-disaster reconstruction project. However, in practice, this instant house faces problems with timber material availability. One solution that can be offered is to use Finger Joint Laminated Board (FJLB) material as a structural component. For the design of earthquake-resistant buildings, one of the components that need to be reviewed carefully is the connection component. In this study, the lateral resistance of the FJLB connection with steel will be reviewed. The connection tool used is a bolt. The joints are tested using a monotonic load in the direction parallel to the grain and perpendicular to the grain. The test results on 12 test objects with the ASTM D-5764-97a standard were then compared with the results of manual calculations using the European Yield Model (EYM) theory listed in Eurocode 5. From the test, the average value of the lateral resistance per bolt was 18.63 kN (parallel to the grain) and 15.22 kN (perpendicular to the grain). The ratio between the value of lateral resistance of the test results and theoretical using EYM is close to a value of 1, where most of the connection failure modes from the test results are close to the theoretical connection failure modes. Thus, it can be concluded that applying the EYM theory to the FJLB connection with steel using a bolt connection is still relevant and gives results that are quite close to the test results.
FJLB双横向磨损胶合板——带有粘螺栓装置的金属板
木材即时住宅(RIKA)是灾后重建项目中推荐的抗震房屋之一。然而,在实践中,这种即时住宅面临着木材材料可用性的问题。一种可以提供的解决方案是使用手指关节层压板(FJLB)材料作为结构组件。对于抗震建筑的设计,其中需要仔细审查的构件之一是连接构件。在本研究中,FJLB连接与钢的横向阻力将进行审查。连接工具为螺栓。采用平行于晶粒和垂直于晶粒方向的单调荷载对接头进行测试。然后用ASTM D-5764-97a标准对12个测试对象的测试结果与使用欧洲规范5中列出的欧洲屈服模型(EYM)理论进行人工计算的结果进行比较。从试验结果来看,每个锚杆的横向阻力平均值为18.63 kN(平行于晶粒)和15.22 kN(垂直于晶粒)。试验结果的侧阻值与EYM理论计算值之比接近于1,其中试验结果得出的大部分连接破坏模式接近于理论连接破坏模式。因此,可以得出结论,将EYM理论应用于使用螺栓连接的钢与FJLB连接仍然是相关的,并且给出的结果与试验结果非常接近。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书