{"title":"Transient resistivity measurements on 345-kV transmission towers","authors":"W. Chisholm, B. Jamali, M. Mathew, J. Driscoll, F. Bologna","doi":"10.1109/SIPDA.2013.6729177","DOIUrl":null,"url":null,"abstract":"A transient injection method was used to simultaneously measure the time variation of footing impedance and soil resistivity on a series of 345-kV steel pole towers. For each tower, the ratio of transient resistivity to impedance, giving an effective tower perimeter, reached an asymptote by 500 ns. The soil resistivity estimates were log-normally distributed with natural log standard deviation of 0.63 for this locale. These time-evolved resistivity values are compared with observations based on frequency domain modeling.","PeriodicalId":216871,"journal":{"name":"2013 International Symposium on Lightning Protection (XII SIPDA)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Symposium on Lightning Protection (XII SIPDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2013.6729177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A transient injection method was used to simultaneously measure the time variation of footing impedance and soil resistivity on a series of 345-kV steel pole towers. For each tower, the ratio of transient resistivity to impedance, giving an effective tower perimeter, reached an asymptote by 500 ns. The soil resistivity estimates were log-normally distributed with natural log standard deviation of 0.63 for this locale. These time-evolved resistivity values are compared with observations based on frequency domain modeling.
345kv输电塔瞬态电阻率测量
采用瞬态注入法同时测量了345kv钢杆塔的基础阻抗和土壤电阻率随时间的变化。对于每个塔,给出有效塔周长的瞬态电阻率与阻抗之比在渐近线处达到500ns。土壤电阻率估计值为对数正态分布,自然对数标准差为0.63。这些随时间变化的电阻率值与基于频域建模的观测结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信