Confocal spatial filtering for imaging with ballistic light in transillumination

M. Kempe, J. Wong, A. Z. Genack
{"title":"Confocal spatial filtering for imaging with ballistic light in transillumination","authors":"M. Kempe, J. Wong, A. Z. Genack","doi":"10.1364/aoipm.1996.pmst25","DOIUrl":null,"url":null,"abstract":"The detection of ballistic and diffuse light in confocal imaging in transillumination is investigated. We find an optimum pinhole size for detection of ballistic and suppression of diffuse light. The limits of confocal imaging with ballistic light are primarily determined by sample parameters. Spherical aberration introduced by the sample is a major limiting factor for high resolution imaging. In the aberration free case and for sample and illumination characteristics which are typical for biomedical imaging, the limits of ballistic light detection in confocal imaging are close to the noise limits of standard detectors.","PeriodicalId":368664,"journal":{"name":"Advances in Optical Imaging and Photon Migration","volume":"518 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Optical Imaging and Photon Migration","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/aoipm.1996.pmst25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The detection of ballistic and diffuse light in confocal imaging in transillumination is investigated. We find an optimum pinhole size for detection of ballistic and suppression of diffuse light. The limits of confocal imaging with ballistic light are primarily determined by sample parameters. Spherical aberration introduced by the sample is a major limiting factor for high resolution imaging. In the aberration free case and for sample and illumination characteristics which are typical for biomedical imaging, the limits of ballistic light detection in confocal imaging are close to the noise limits of standard detectors.
透照弹道光成像的共聚焦空间滤波
研究了透照共聚焦成像中弹道光和漫射光的检测。我们找到了检测弹道和抑制漫射光的最佳针孔尺寸。弹道光共聚焦成像的极限主要由样品参数决定。样品引入的球差是高分辨率成像的主要限制因素。在无像差的情况下,对于生物医学成像中典型的样品和照明特性,共聚焦成像中的弹道光检测极限接近标准检测器的噪声极限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信