{"title":"Input current distortion of CCM boost PFC converters operated in DCM","authors":"K. De Gusseme, D. Van de Sype, A. Van den Bossche, J. Melkebeek","doi":"10.1109/PESC.2003.1217710","DOIUrl":null,"url":null,"abstract":"Power factor correction (PFC) converters for the higher power range are commonly designed for continuous conduction mode (CCM). Nevertheless, operation in the discontinuous conduction mode (DCM) occurs for light load in a zone, close to the crossover of the line voltage. This zone will gradually expand with decreasing load to finally encompass the entire line cycle. Whereas in CCM the parasitic capacitances of the switches only cause switching losses, in DCM they are a source of converter instability, resulting in significant input current distortion. In this paper, this source of input current distortion is analyzed and a solution is proposed. Experimental results are obtained using a digitally controlled boost PFC converter, designed to operate in CCM for 1 kW.","PeriodicalId":236199,"journal":{"name":"IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03.","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"72","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.2003.1217710","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 72

Abstract

Power factor correction (PFC) converters for the higher power range are commonly designed for continuous conduction mode (CCM). Nevertheless, operation in the discontinuous conduction mode (DCM) occurs for light load in a zone, close to the crossover of the line voltage. This zone will gradually expand with decreasing load to finally encompass the entire line cycle. Whereas in CCM the parasitic capacitances of the switches only cause switching losses, in DCM they are a source of converter instability, resulting in significant input current distortion. In this paper, this source of input current distortion is analyzed and a solution is proposed. Experimental results are obtained using a digitally controlled boost PFC converter, designed to operate in CCM for 1 kW.
在DCM中工作的CCM升压PFC变换器的输入电流畸变
高功率范围的功率因数校正(PFC)转换器通常设计用于连续导通模式(CCM)。然而,在一个区域内,在接近线电压交叉点的地方,轻负载会发生断续导通模式(DCM)。该区域将随着负荷的减少而逐渐扩大,最终覆盖整个线路周期。在CCM中,开关的寄生电容只引起开关损耗,而在DCM中,它们是转换器不稳定的来源,导致显著的输入电流畸变。本文分析了这种输入电流畸变的来源,并提出了解决方法。实验结果是用一个数字控制升压PFC变换器,设计工作在1千瓦的CCM。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信