Electrostatic field analysis and verification of air cooled generator end turn insulation models

F. Emery, J. Roach
{"title":"Electrostatic field analysis and verification of air cooled generator end turn insulation models","authors":"F. Emery, J. Roach","doi":"10.1109/EEIC.1999.826236","DOIUrl":null,"url":null,"abstract":"Electrostatic field analysis was performed on generic electrodes for assessment of generator end turn electrical insulation design. A number of coil end turn configurations were analyzed near highly stressed electrode corners and along support block creep surfaces for various insulation thickness, and a range of air gap spacings. A finite element electrostatics code was employed to generate two dimensional equipotential plots for insulated electrodes with and without dielectric support blocks. Empirical theories based upon local stress enhancement were used to estimate corona onset, creep discharge, and spark breakdown as a function of insulation thickness and air gap spacing. The corona onset calculations were verified using actual test setups and monitoring the corona with the Corona Scope/sup TM/. Sparkover tests were also done to verify the calculations.","PeriodicalId":415071,"journal":{"name":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.99CH37035)","volume":"307 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.99CH37035)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.1999.826236","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Electrostatic field analysis was performed on generic electrodes for assessment of generator end turn electrical insulation design. A number of coil end turn configurations were analyzed near highly stressed electrode corners and along support block creep surfaces for various insulation thickness, and a range of air gap spacings. A finite element electrostatics code was employed to generate two dimensional equipotential plots for insulated electrodes with and without dielectric support blocks. Empirical theories based upon local stress enhancement were used to estimate corona onset, creep discharge, and spark breakdown as a function of insulation thickness and air gap spacing. The corona onset calculations were verified using actual test setups and monitoring the corona with the Corona Scope/sup TM/. Sparkover tests were also done to verify the calculations.
风冷发电机端匝绝缘模型的静电场分析与验证
对通用电极进行静电场分析,评价发电机端匝电绝缘设计。在不同的绝缘厚度和气隙间距下,分析了靠近高应力电极角和沿支撑块蠕变表面的许多线圈端匝配置。采用有限元静电程序对有无介质支撑块的绝缘电极进行了二维等电位图的生成。基于局部应力增强的经验理论用于估计电晕发作、蠕变放电和火花击穿作为绝缘厚度和气隙间距的函数。通过实际测试设置和使用corona Scope/sup TM/监测电晕,验证了电晕开始计算。还进行了火花试验来验证计算结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信