One-Dimensional Modelling of Piezo-Structure Interaction for DeBonding Configuration using Electro-Mechanical Impedance (EMI) Techniques

S. Moharana, D. S
{"title":"One-Dimensional Modelling of Piezo-Structure Interaction for DeBonding Configuration using Electro-Mechanical Impedance (EMI) Techniques","authors":"S. Moharana, D. S","doi":"10.1109/IYCE45807.2019.8991595","DOIUrl":null,"url":null,"abstract":"For electro-mechanical impedance (EMI) technique based Structural Health Monitoring (SHM), the piezo ceramic patches are employed with adhesive bond to evaluate and diagnose the host structure to be monitored. The adhesive bond forms a definite layer for force transmission between the patch and host structure. The mechanical and geometrical properties of the adhesive bond layer has significant effect on the overall performance of the PZT-structure interaction. This paper represents the effect geometrical deformation bonding area in the coupled admittance signature through mathematical modelling. The debonding effect has modelled for piezo elasto- dynamic system. In this paper, the mathematical modelling for 1D piezo elastic structure for debonding case and the results are compared with perfect bonding and definite bonding of adhesive bond for PZT-Structure interaction. The paper also studied parametric variation of bond parameter to examine the influence on the EMI based structural signature.","PeriodicalId":226881,"journal":{"name":"2019 7th International Youth Conference on Energy (IYCE)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 7th International Youth Conference on Energy (IYCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IYCE45807.2019.8991595","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

For electro-mechanical impedance (EMI) technique based Structural Health Monitoring (SHM), the piezo ceramic patches are employed with adhesive bond to evaluate and diagnose the host structure to be monitored. The adhesive bond forms a definite layer for force transmission between the patch and host structure. The mechanical and geometrical properties of the adhesive bond layer has significant effect on the overall performance of the PZT-structure interaction. This paper represents the effect geometrical deformation bonding area in the coupled admittance signature through mathematical modelling. The debonding effect has modelled for piezo elasto- dynamic system. In this paper, the mathematical modelling for 1D piezo elastic structure for debonding case and the results are compared with perfect bonding and definite bonding of adhesive bond for PZT-Structure interaction. The paper also studied parametric variation of bond parameter to examine the influence on the EMI based structural signature.
基于机电阻抗(EMI)技术的脱粘态压电结构相互作用的一维建模
基于电磁阻抗(EMI)技术的结构健康监测(SHM),采用压电陶瓷贴片与粘接结合的方法对被监测主体结构进行评估和诊断。粘合剂在贴片和主体结构之间形成一定的力传递层。粘接层的力学和几何性能对pzt -结构相互作用的整体性能有显著影响。本文通过数学建模,阐述了几何变形结合面积对耦合导纳信号的影响。建立了压电弹性动力系统的脱粘效应模型。本文建立了一维压电弹性结构脱粘情况下的数学模型,并与PZT-Structure相互作用的完全粘接和确定粘接结果进行了比较。本文还研究了键参数的变化对基于电磁干扰的结构特征的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信