{"title":"Performance evaluation of PRIME PLC modems over distribution transformers in Indian context","authors":"Konark Sharma, L. Saini","doi":"10.1049/PBPO132E_CH13","DOIUrl":null,"url":null,"abstract":"The past few years have witnessed a tremendous development in powerline intelligent metering evolution (PRIME) technology for high speed data communication across medium voltage (MV) and low voltage (LV) transmission/distribution networks based smart grid (SG) applications. PRIME PLC (PRIME power-line communication) technology also elucidates the importance of employing robust modulation schemes across distribution-transformers and motivates research in this direction. Indeed, the aim of the chapter is to investigate PRIME channel measurements through MV/LV distribution transformers by implementing experimental tests to analyze the signal-to-noise ratio (SNR), bit error rate (BER) and packet error rate (PER) performance of differential binary phase shift keying (DBPSK), differential quadrature phase shift keying (DQPSK) and eight-ary differential phase shift keying (D8PSK) modulation schemes over multipath PLC channels in Indian context.","PeriodicalId":282284,"journal":{"name":"Power Line Communication Systems for Smart Grids","volume":"200 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Power Line Communication Systems for Smart Grids","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/PBPO132E_CH13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The past few years have witnessed a tremendous development in powerline intelligent metering evolution (PRIME) technology for high speed data communication across medium voltage (MV) and low voltage (LV) transmission/distribution networks based smart grid (SG) applications. PRIME PLC (PRIME power-line communication) technology also elucidates the importance of employing robust modulation schemes across distribution-transformers and motivates research in this direction. Indeed, the aim of the chapter is to investigate PRIME channel measurements through MV/LV distribution transformers by implementing experimental tests to analyze the signal-to-noise ratio (SNR), bit error rate (BER) and packet error rate (PER) performance of differential binary phase shift keying (DBPSK), differential quadrature phase shift keying (DQPSK) and eight-ary differential phase shift keying (D8PSK) modulation schemes over multipath PLC channels in Indian context.