Photoplethysmogram(PPG) and Phonocardiogram(PCG) integrated circuits for multi-mode health monitoring system on the chest

Minseok Park, Jae Joon Kim
{"title":"Photoplethysmogram(PPG) and Phonocardiogram(PCG) integrated circuits for multi-mode health monitoring system on the chest","authors":"Minseok Park, Jae Joon Kim","doi":"10.1109/ICEIC57457.2023.10049854","DOIUrl":null,"url":null,"abstract":"This paper presents PPG and PCG integrated circuits for multi-mode health monitoring system on the chest. Using chopper-stabilization technique and improved noise shaping loop, the noise of the core amplifier in the integrator and the quantization error are reduced in PPG ROIC. The PPG ROIC has a 116.9dB DR and achieves a maximum 92.7dB SNR. Also, Dual peak detector to distinguish PCG S1, S2 peak is introduced. The prototype is fabricated with 0.18 μm BCD process and multi-mode health monitoring system, can be operated as digital-stethoscope, heart-rate monitor, and VTT based BP monitor, implemented in MATLAB program.","PeriodicalId":373752,"journal":{"name":"2023 International Conference on Electronics, Information, and Communication (ICEIC)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 International Conference on Electronics, Information, and Communication (ICEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEIC57457.2023.10049854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents PPG and PCG integrated circuits for multi-mode health monitoring system on the chest. Using chopper-stabilization technique and improved noise shaping loop, the noise of the core amplifier in the integrator and the quantization error are reduced in PPG ROIC. The PPG ROIC has a 116.9dB DR and achieves a maximum 92.7dB SNR. Also, Dual peak detector to distinguish PCG S1, S2 peak is introduced. The prototype is fabricated with 0.18 μm BCD process and multi-mode health monitoring system, can be operated as digital-stethoscope, heart-rate monitor, and VTT based BP monitor, implemented in MATLAB program.
用于胸部多模式健康监测系统的光电容积图(PPG)和心音图(PCG)集成电路
介绍了用于胸部多模式健康监测系统的PPG和PCG集成电路。利用斩波稳定技术和改进的噪声整形回路,降低了积分器中核心放大器的噪声和量化误差。PPG ROIC的DR为116.9dB,最大信噪比为92.7dB。此外,还介绍了用于区分PCG S1、S2峰的双峰检测器。该样机采用0.18 μm BCD工艺和多模式健康监测系统制作而成,可作为数字听诊器、心率监测仪和基于VTT的血压监测仪使用,并通过MATLAB编程实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信