A 22 MeV microtron for radiation therapy.

H Svensson, L Jonsson, L G Larsson, A Brahme, B Lindberg, D Reistad
{"title":"A 22 MeV microtron for radiation therapy.","authors":"H Svensson,&nbsp;L Jonsson,&nbsp;L G Larsson,&nbsp;A Brahme,&nbsp;B Lindberg,&nbsp;D Reistad","doi":"10.3109/02841867709134308","DOIUrl":null,"url":null,"abstract":"<p><p>The first 22 MeV micron installation for radiation therapy is described with regard to the general design, the beam transport and the gantry. The first measurements of the electron depth dose curves indicate that the distributions obtained are superior to those of most betatrons and linear accelerators. For the same electron beam energy the depth of dose maximum and the 90 or 80 per cent dose level is considerably increased. The 20.9 MV photon beam has similar depth dose characteristics as a 20 MV betatron.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"16 2","pages":"145-56"},"PeriodicalIF":0.0000,"publicationDate":"1977-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867709134308","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica: therapy, physics, biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/02841867709134308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

The first 22 MeV micron installation for radiation therapy is described with regard to the general design, the beam transport and the gantry. The first measurements of the electron depth dose curves indicate that the distributions obtained are superior to those of most betatrons and linear accelerators. For the same electron beam energy the depth of dose maximum and the 90 or 80 per cent dose level is considerably increased. The 20.9 MV photon beam has similar depth dose characteristics as a 20 MV betatron.

用于放射治疗的22兆电子伏特微电子管。
第一个22 MeV微米的放射治疗装置描述了总体设计,光束传输和龙门架。对电子深度剂量曲线的初步测量表明,所得到的分布优于大多数电子加速器和直线加速器。对于相同的电子束能量,最大剂量深度和90%或80%剂量水平显著增加。20.9 MV的光子束与20 MV的电子加速器具有相似的深度剂量特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信