{"title":"Analysis and localization of spurious partial discharge activity in generator units","authors":"A. Pemen, P.C.T. van der Laan, W. de Leeuw","doi":"10.1109/ICSD.2001.955703","DOIUrl":null,"url":null,"abstract":"Partial discharge (PD) measurements are an effective tool to assess the condition of important power plant components, such as the generator, the generator circuit-breaker and the step-up transformer.This paper shows that, in addition to phase-resolved patterns, the waveshapes of PD signals provide valuable information on the type and origin of the discharges. The authors describe the complex propagation of PD signals in a stator winding and the consequences for PD detection. Results from on-line measurements in three power plants where abnormal PD activity was observed are presented. In all cases the source of the PD's ccan be located: (i) slot discharges in a 125 MW generator, (ii) interphase discharges in the end-windings of a 165 MW generator, and (iii) an improperly installed bleeding resistor in a generator-circuit breaker.","PeriodicalId":239585,"journal":{"name":"ICSD'01. Proceedings of the 20001 IEEE 7th International Conference on Solid Dielectrics (Cat. No.01CH37117)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICSD'01. Proceedings of the 20001 IEEE 7th International Conference on Solid Dielectrics (Cat. No.01CH37117)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.2001.955703","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
Partial discharge (PD) measurements are an effective tool to assess the condition of important power plant components, such as the generator, the generator circuit-breaker and the step-up transformer.This paper shows that, in addition to phase-resolved patterns, the waveshapes of PD signals provide valuable information on the type and origin of the discharges. The authors describe the complex propagation of PD signals in a stator winding and the consequences for PD detection. Results from on-line measurements in three power plants where abnormal PD activity was observed are presented. In all cases the source of the PD's ccan be located: (i) slot discharges in a 125 MW generator, (ii) interphase discharges in the end-windings of a 165 MW generator, and (iii) an improperly installed bleeding resistor in a generator-circuit breaker.