Time Efficient Reverberation Chamber Performance Analysis Using Simultaneous Multiprobe Measurement Technique

Dwi Mandaris, R. Vogt-Ardatjew, Mhd Zaher Mahfouz, E. Suthau, F. Leferink
{"title":"Time Efficient Reverberation Chamber Performance Analysis Using Simultaneous Multiprobe Measurement Technique","authors":"Dwi Mandaris, R. Vogt-Ardatjew, Mhd Zaher Mahfouz, E. Suthau, F. Leferink","doi":"10.1109/EMCEUROPE.2018.8485001","DOIUrl":null,"url":null,"abstract":"This paper describes simultaneous multiprobe measurement technique for performance analysis of a mode-stirring classical reverberation chamber with three different shapes of the stirrer, which are irregular Z-folded, a single-plate stirrer and an asymmetrical irregular folded. Measurements were carried out by using very fast and accurate 9 3D electric field probes, energized via a laser and readout via an optical link, thus not disturbing the electromagnetic field. Two important parameters were analysed: field uniformity and the number of independent samples using the ‘standard method’ and the ‘general method’. The fast multi-probe system allows very fast evaluation of the reverberation chamber, the effectiveness of stirrers and assessment of the spatial field uniformity.","PeriodicalId":376960,"journal":{"name":"2018 International Symposium on Electromagnetic Compatibility (EMC EUROPE)","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Symposium on Electromagnetic Compatibility (EMC EUROPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE.2018.8485001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This paper describes simultaneous multiprobe measurement technique for performance analysis of a mode-stirring classical reverberation chamber with three different shapes of the stirrer, which are irregular Z-folded, a single-plate stirrer and an asymmetrical irregular folded. Measurements were carried out by using very fast and accurate 9 3D electric field probes, energized via a laser and readout via an optical link, thus not disturbing the electromagnetic field. Two important parameters were analysed: field uniformity and the number of independent samples using the ‘standard method’ and the ‘general method’. The fast multi-probe system allows very fast evaluation of the reverberation chamber, the effectiveness of stirrers and assessment of the spatial field uniformity.
基于多探头同步测量技术的时效混响室性能分析
本文介绍了三种不同形状的搅拌器(不规则z型折叠、单板搅拌和非对称不规则折叠)的模态搅拌经典混响室的同时多探头测量技术。测量是通过使用非常快速和精确的9个3D电场探头进行的,通过激光供电,通过光学链路读取,因此不会干扰电磁场。使用“标准方法”和“一般方法”分析了两个重要参数:现场均匀性和独立样本数量。快速多探头系统可以非常快速地评估混响室,搅拌器的有效性和评估空间场均匀性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信