{"title":"Architecture for a Modular Temperature Detection System Used for Diabetic Foot Investigations","authors":"M. Serbanescu, Florin Nastase, F. Draghici, G. Pristavu, E. Catrina, R. Chiriac, G. Brezeanu","doi":"10.1109/CAS56377.2022.9934331","DOIUrl":null,"url":null,"abstract":"Feet ulcerations represent a prevalent and severe complication of diabetes. This paper presents an architecture for a modular temperature gradient detection system. The solution allows scanning of the plantar regions as a key driver for an accurate identification of local inflammations, prior to ulcer development. It comprises two parallel strings of sensing modules, serially connected to a main board, which facilitates both data acquisition and data transmission to a computer. The system demonstrated measurement resolution as low as 0.05°C and response time of circa 60 seconds. The active mode current consumption (17 mA) enables the usage of a battery supply, increasing portability, safety and ease-of-operation.","PeriodicalId":380138,"journal":{"name":"2022 International Semiconductor Conference (CAS)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Semiconductor Conference (CAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CAS56377.2022.9934331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Feet ulcerations represent a prevalent and severe complication of diabetes. This paper presents an architecture for a modular temperature gradient detection system. The solution allows scanning of the plantar regions as a key driver for an accurate identification of local inflammations, prior to ulcer development. It comprises two parallel strings of sensing modules, serially connected to a main board, which facilitates both data acquisition and data transmission to a computer. The system demonstrated measurement resolution as low as 0.05°C and response time of circa 60 seconds. The active mode current consumption (17 mA) enables the usage of a battery supply, increasing portability, safety and ease-of-operation.