{"title":"Performance Assessment of the αβ0-Based Bus Differential Protection","authors":"S. Saleh, E. Ozkop, R. Ahshan, A. Al‐Durra, M. Valdes, C. Mardegan","doi":"10.1109/ICPS54075.2022.9773888","DOIUrl":null,"url":null,"abstract":"This paper presents the experimental performance assessment of the αβ0-based bus differential protection (BDP). This protection is developed for buses that interconnect battery storage systems (BSSs). The tested BDP employs αβ0 components of the apparent powers flowing in all branches that are connected to the protected bus. The αβ0 components of apparent powers allow accommodating frequent changes in the direction of power flows due to the charging/discharging modes of the BSS operation. In each branch connected to the protected bus, the 3φ apparent powers are determined using the measured branch currents and voltage (at the protected bus). The αβ0-based BDP is implemented using a digital processing board for experimental testing for a laboratory setup. The test setup is composed of a bus that interconnects a 4 kW BSS, and feeds 3φ linear and dynamic loads. The performance of the αβ0-based BDP is assessed for responding to various internal and external faults occurring during the charging and discharging of the BSS. Experimental results reveal encouraging abilities of the tested BDP to initiate fast, accurate, and reliable responses to internal and external faults. Observed response features are complimented with a minor sensitivity to the BSS mode of operation, fault type, and/or fault location.","PeriodicalId":428784,"journal":{"name":"2022 IEEE/IAS 58th Industrial and Commercial Power Systems Technical Conference (I&CPS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE/IAS 58th Industrial and Commercial Power Systems Technical Conference (I&CPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS54075.2022.9773888","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper presents the experimental performance assessment of the αβ0-based bus differential protection (BDP). This protection is developed for buses that interconnect battery storage systems (BSSs). The tested BDP employs αβ0 components of the apparent powers flowing in all branches that are connected to the protected bus. The αβ0 components of apparent powers allow accommodating frequent changes in the direction of power flows due to the charging/discharging modes of the BSS operation. In each branch connected to the protected bus, the 3φ apparent powers are determined using the measured branch currents and voltage (at the protected bus). The αβ0-based BDP is implemented using a digital processing board for experimental testing for a laboratory setup. The test setup is composed of a bus that interconnects a 4 kW BSS, and feeds 3φ linear and dynamic loads. The performance of the αβ0-based BDP is assessed for responding to various internal and external faults occurring during the charging and discharging of the BSS. Experimental results reveal encouraging abilities of the tested BDP to initiate fast, accurate, and reliable responses to internal and external faults. Observed response features are complimented with a minor sensitivity to the BSS mode of operation, fault type, and/or fault location.
基于αβ0的母线差动保护性能评价
本文给出了基于αβ0的母线差动保护(BDP)的实验性能评估。这种保护是为连接电池存储系统(bss)的总线开发的。测试的BDP采用连接到受保护母线的所有支路中流动的视在功率的αβ0分量。视在功率的αβ0分量允许适应由于BSS操作的充电/放电模式而导致的功率流方向的频繁变化。在连接到受保护母线的每个支路中,使用测量的支路电流和电压(在受保护母线处)确定3φ视在功率。基于αβ0的BDP使用数字处理板实现,用于实验室设置的实验测试。测试装置由一个总线组成,该总线连接一个4kw BSS,并提供3φ线性和动态负载。评价了基于αβ0的BDP在充放电过程中对各种内部和外部故障的响应性能。实验结果表明,测试的BDP能够对内部和外部故障进行快速、准确和可靠的响应。观察到的响应特征与BSS操作模式、故障类型和/或故障位置的轻微敏感性相辅相成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信