Analysis of and Inductance Estimation for Half-Controlled Thyristor Converters

S. Palanichamy, V. Subbiah
{"title":"Analysis of and Inductance Estimation for Half-Controlled Thyristor Converters","authors":"S. Palanichamy, V. Subbiah","doi":"10.1109/TIECI.1981.351083","DOIUrl":null,"url":null,"abstract":"Operating diagrams are developed for single-phase as well as three-phase half-controlled thyristor converters connected to a general resistive, inductive, and EMF load. With the help of these diagrams, modes of operation of such converters are identified. Once the operating mode is identified for any given set of load circuit parameters and trigger angle, then the corresponding equations can be chosen with which the performance analysis can be carried out. Minimum inductance necessary in the load circuit for continuous current operation of three-phase converters is evaluated through a method wherein the load circuit resistance is neglected. A graphical solution is given for the evaluation of minimum inductance in those cases where the load circuit resistance may not be negligible.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"223 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1981-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Industrial Electronics and Control Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIECI.1981.351083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Operating diagrams are developed for single-phase as well as three-phase half-controlled thyristor converters connected to a general resistive, inductive, and EMF load. With the help of these diagrams, modes of operation of such converters are identified. Once the operating mode is identified for any given set of load circuit parameters and trigger angle, then the corresponding equations can be chosen with which the performance analysis can be carried out. Minimum inductance necessary in the load circuit for continuous current operation of three-phase converters is evaluated through a method wherein the load circuit resistance is neglected. A graphical solution is given for the evaluation of minimum inductance in those cases where the load circuit resistance may not be negligible.
半控制晶闸管变换器的分析与电感估计
工作图开发单相以及三相半控制晶闸管变换器连接到一般电阻,电感和电动势负载。在这些图的帮助下,确定了这种转换器的运行模式。一旦确定了任意一组负载电路参数和触发角度的工作模式,就可以选择相应的方程进行性能分析。通过一种忽略负载电路电阻的方法来评估三相变流器连续电流运行所需的负载电路中的最小电感。在负载电路电阻不可忽略的情况下,给出了最小电感的图解解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书