Mathematical model and experimental methodology for calibration of a LWIR polarimetric-hyperspectral imager

Joel G. Holder, Jacob A. Martin, K. Gross
{"title":"Mathematical model and experimental methodology for calibration of a LWIR polarimetric-hyperspectral imager","authors":"Joel G. Holder, Jacob A. Martin, K. Gross","doi":"10.1109/AIPR.2014.7041909","DOIUrl":null,"url":null,"abstract":"Polarimetric-hyperspectral imaging brings two traditionally independent modalities together to potentially enhance scene characterization capabilities. This could increase confidence in target detection, material identification, and background characterization over traditional hyperspectral imaging. In order to fully exploit the spectro-polarimetric signal, a careful calibration process is required to remove both the radiometric and polarimetric response of the system (gain). In the long-wave infrared, calibration is further complicated by the polarized self-emission of the instrument itself (offset). This paper presents both the mathematical framework and the experimental methodology for the spectro-polarimetric calibration of a long-wave infrared (LWIR) Telops Hyper-Cam which has been modified with a rotatable wire-grid polarizer at the entrance aperture. The mathematical framework is developed using a Mueller matrix approach to model the polarimetric effects of the system, and this is combined with a standard Fourier-transform spectrometer (FTS) radiometric calibration framework. This is done for two cases: one assuming that the instrument polarizer is ideal, and a second method which accounts for a non-ideal instrument polarizer. It is shown that a standard two-point radiometric calibration at each instrument polarizer angle is sufficient to remove the polarimetric bias of the instrument, if the instrument polarizer can be assumed to be ideal. For the non-ideal polarizer case, the system matrix and the Mueller deviation matrix is experimentally determined for the system, and used to quantify how non-ideal the system is. The noise-equivalent spectral radiance and DoLP are also quantified using a wide-area blackbody. Finally, a scene with a variety of features in it is imaged and analyzed.","PeriodicalId":210982,"journal":{"name":"2014 IEEE Applied Imagery Pattern Recognition Workshop (AIPR)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Applied Imagery Pattern Recognition Workshop (AIPR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AIPR.2014.7041909","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Polarimetric-hyperspectral imaging brings two traditionally independent modalities together to potentially enhance scene characterization capabilities. This could increase confidence in target detection, material identification, and background characterization over traditional hyperspectral imaging. In order to fully exploit the spectro-polarimetric signal, a careful calibration process is required to remove both the radiometric and polarimetric response of the system (gain). In the long-wave infrared, calibration is further complicated by the polarized self-emission of the instrument itself (offset). This paper presents both the mathematical framework and the experimental methodology for the spectro-polarimetric calibration of a long-wave infrared (LWIR) Telops Hyper-Cam which has been modified with a rotatable wire-grid polarizer at the entrance aperture. The mathematical framework is developed using a Mueller matrix approach to model the polarimetric effects of the system, and this is combined with a standard Fourier-transform spectrometer (FTS) radiometric calibration framework. This is done for two cases: one assuming that the instrument polarizer is ideal, and a second method which accounts for a non-ideal instrument polarizer. It is shown that a standard two-point radiometric calibration at each instrument polarizer angle is sufficient to remove the polarimetric bias of the instrument, if the instrument polarizer can be assumed to be ideal. For the non-ideal polarizer case, the system matrix and the Mueller deviation matrix is experimentally determined for the system, and used to quantify how non-ideal the system is. The noise-equivalent spectral radiance and DoLP are also quantified using a wide-area blackbody. Finally, a scene with a variety of features in it is imaged and analyzed.
LWIR偏振-高光谱成像仪定标的数学模型和实验方法
偏振-高光谱成像将两种传统上独立的模式结合在一起,潜在地增强了场景表征能力。与传统的高光谱成像相比,这可以增加目标检测、材料识别和背景表征的信心。为了充分利用光谱偏振信号,需要仔细的校准过程来消除系统的辐射和偏振响应(增益)。在长波红外中,由于仪器本身的偏振自发射(偏移),校准变得更加复杂。本文给出了长波红外(LWIR) Telops Hyper-Cam的光谱偏振定标的数学框架和实验方法,该定标是在长波红外(LWIR)的入口孔径处安装了可旋转的线栅偏振器。使用Mueller矩阵方法建立了数学框架,以模拟系统的极化效应,并将其与标准傅立叶变换光谱仪(FTS)辐射校准框架相结合。这是在两种情况下完成的:一种假设仪器偏光片是理想的,第二种方法是考虑非理想仪器偏光片。结果表明,如果仪器偏振片可以假设为理想的,则在每个仪器偏振片角度上进行标准两点辐射校准就足以消除仪器的偏振片偏置。对于非理想偏振器,系统矩阵和穆勒偏差矩阵是实验确定的系统,并用于量化系统的非理想程度。噪声等效光谱辐射和DoLP也用广域黑体进行了量化。最后,对一个具有多种特征的场景进行成像和分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信