A. Poghosyan, Tigran A Muradyan, Norik E Grigoryan
{"title":"Comparison Evaluation of Periimplant Alveolar Crest Stress/Strain Distribution Ability Depending on Alveolar Bone Density: Mathematical Model","authors":"A. Poghosyan, Tigran A Muradyan, Norik E Grigoryan","doi":"10.4172/2376-032X.1000178","DOIUrl":null,"url":null,"abstract":"The aim of this study was to evaluate the biomechanical response of the periimplant bone stress/strain ability to loading forces depending on bone type. The mathematical model analysis was chosen for the present study as it has proved to be a useful tool in estimating stress distribution in the contact area of the implant with surrounding bone. The calculations were aimed to show the differences of strain forces (F) distribution ability depending of bone types (D1, D2, D3, D4). The different bone types with the same V volume arise different strain forces. When comparing these values we see that and differ from in 3 and 5 times respectively, so and types of bones have 3 and 5 times less strain distribution ability than the type bone.","PeriodicalId":110010,"journal":{"name":"JBR Journal of Interdisciplinary Medicine and Dental Science","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JBR Journal of Interdisciplinary Medicine and Dental Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2376-032X.1000178","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of this study was to evaluate the biomechanical response of the periimplant bone stress/strain ability to loading forces depending on bone type. The mathematical model analysis was chosen for the present study as it has proved to be a useful tool in estimating stress distribution in the contact area of the implant with surrounding bone. The calculations were aimed to show the differences of strain forces (F) distribution ability depending of bone types (D1, D2, D3, D4). The different bone types with the same V volume arise different strain forces. When comparing these values we see that and differ from in 3 and 5 times respectively, so and types of bones have 3 and 5 times less strain distribution ability than the type bone.