An Image Quality Assessment System for Evaluating MR Reconstruction Pipeline Using Single Image Acquisition Method

Sunny Sibi, T. S. Pillai, P. S. Chandran, N. NishaKumari, O. RanjithK, M. Deepak, P. Devanand
{"title":"An Image Quality Assessment System for Evaluating MR Reconstruction Pipeline Using Single Image Acquisition Method","authors":"Sunny Sibi, T. S. Pillai, P. S. Chandran, N. NishaKumari, O. RanjithK, M. Deepak, P. Devanand","doi":"10.2139/ssrn.3736531","DOIUrl":null,"url":null,"abstract":"Image quality assessment becomes critical for measuring the performance of Magnetic Resonance (MR) image reconstruction algorithms. The raw data acquired from MR scanner is processed through a series of components in the MR reconstruction pipeline to generate an image. The MR reconstruction pipeline includes the algorithms for reconstruction, quality enhancement, artifact reduction, and so on. The implementation of the pipeline requires evaluation of large number of filters and reconstruction algorithms, which demands a simple and effective mechanism to assess the quality of output at each stage. The main goal of the proposed work is to provide research groups and MR algorithm developers with protocols and tools necessary to conveniently assess the quality of MR images and to be able to compare the reconstruction methods among each other. This paper focuses on the implementation of an image quality assessment mechanism using the single image method by specifying Region of Interest (ROI) from object and background as suggested by National Electrical Manufacturers Association (NEMA). The single image method does not produce consistent results as the SNR values change drastically based on the background noise. It has been observed that, by careful selection of noise region, the drastic changes in values of SNR can be avoided with single acquisition techniques. This mechanism is supported by a visual aiding tool to carefully select signal and noise regions and avoid the errors introduced in blind selection of ROI. Using the single acquisition method and visual aiding tool, SNR comparison of images from two different reconstruction methods can be easily evaluated.","PeriodicalId":175553,"journal":{"name":"Informatics eJournal","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Informatics eJournal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2139/ssrn.3736531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Image quality assessment becomes critical for measuring the performance of Magnetic Resonance (MR) image reconstruction algorithms. The raw data acquired from MR scanner is processed through a series of components in the MR reconstruction pipeline to generate an image. The MR reconstruction pipeline includes the algorithms for reconstruction, quality enhancement, artifact reduction, and so on. The implementation of the pipeline requires evaluation of large number of filters and reconstruction algorithms, which demands a simple and effective mechanism to assess the quality of output at each stage. The main goal of the proposed work is to provide research groups and MR algorithm developers with protocols and tools necessary to conveniently assess the quality of MR images and to be able to compare the reconstruction methods among each other. This paper focuses on the implementation of an image quality assessment mechanism using the single image method by specifying Region of Interest (ROI) from object and background as suggested by National Electrical Manufacturers Association (NEMA). The single image method does not produce consistent results as the SNR values change drastically based on the background noise. It has been observed that, by careful selection of noise region, the drastic changes in values of SNR can be avoided with single acquisition techniques. This mechanism is supported by a visual aiding tool to carefully select signal and noise regions and avoid the errors introduced in blind selection of ROI. Using the single acquisition method and visual aiding tool, SNR comparison of images from two different reconstruction methods can be easily evaluated.
基于单图像采集方法的磁共振重建管道图像质量评估系统
图像质量评估对于测量磁共振(MR)图像重建算法的性能至关重要。从磁共振扫描仪获取的原始数据通过磁共振重建流水线中的一系列组件进行处理以生成图像。磁共振重建流水线包括重建、质量增强、伪影减少等算法。流水线的实现需要对大量的滤波器和重建算法进行评估,这就需要一种简单有效的机制来评估每个阶段的输出质量。所提出的工作的主要目标是为研究小组和MR算法开发人员提供必要的协议和工具,以方便地评估MR图像的质量,并能够相互比较重建方法。本文根据美国电气制造商协会(NEMA)的建议,通过从目标和背景指定感兴趣区域(ROI),重点研究了使用单幅图像方法的图像质量评估机制的实现。单幅图像的方法不能得到一致的结果,因为信噪比值会随着背景噪声的变化而剧烈变化。已经观察到,通过仔细选择噪声区域,单采集技术可以避免信噪比值的剧烈变化。该机制由视觉辅助工具支持,以仔细选择信号和噪声区域,避免盲目选择ROI带来的误差。利用单采集方法和可视化辅助工具,可以方便地评价两种不同重建方法图像的信噪比对比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信