Impulse Voltage-based Test Method for Identifying the Stator Insulation Component with PD Activity for Low Voltage AC Motors

Sang Bin Lee, Alireza Naeini, S. Jayaram, G. Stone, M. Šašić
{"title":"Impulse Voltage-based Test Method for Identifying the Stator Insulation Component with PD Activity for Low Voltage AC Motors","authors":"Sang Bin Lee, Alireza Naeini, S. Jayaram, G. Stone, M. Šašić","doi":"10.1109/EIC43217.2019.9046584","DOIUrl":null,"url":null,"abstract":"IEC 60034-18-41 has been developed as a standard acceptance test to ensure partial discharge (PD)-free operation for improving the reliability of low voltage (LV) variable frequency drive (VFD) motors. Although the test can verify whether PD exists in the stator for a voltage surge with predetermined magnitude and risetime, the information on where PD activity is occurring in the stator insulation is not clearly given. In this paper, a method based on variable risetime surge voltage testing is proposed for identifying the component of the stator insulation system where PD occurs in LV random wound motor stators (turn, phase, or ground insulation). This information can be used for increasing the PD inception voltage for improving the reliability of the motor through insulation system design/manufacturing. The test is implemented with a 4.5 kV variable risetime surge generator prototype. 4 LV ac motors are tested to show where PD is likely to occur in commercial LV motors.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"11 21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046584","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

IEC 60034-18-41 has been developed as a standard acceptance test to ensure partial discharge (PD)-free operation for improving the reliability of low voltage (LV) variable frequency drive (VFD) motors. Although the test can verify whether PD exists in the stator for a voltage surge with predetermined magnitude and risetime, the information on where PD activity is occurring in the stator insulation is not clearly given. In this paper, a method based on variable risetime surge voltage testing is proposed for identifying the component of the stator insulation system where PD occurs in LV random wound motor stators (turn, phase, or ground insulation). This information can be used for increasing the PD inception voltage for improving the reliability of the motor through insulation system design/manufacturing. The test is implemented with a 4.5 kV variable risetime surge generator prototype. 4 LV ac motors are tested to show where PD is likely to occur in commercial LV motors.
识别低压交流电动机定子绝缘元件的脉冲电压试验方法
IEC 60034-18-41已被开发为标准验收测试,以确保无局部放电(PD)运行,以提高低压(LV)变频驱动(VFD)电机的可靠性。虽然该测试可以验证定子中是否存在具有预定幅度和上升时间的电压浪涌,但关于定子绝缘中PD活动发生的位置的信息并没有明确给出。本文提出了一种基于变上升时间浪涌电压测试的方法,用于识别低压无绕组电机定子绝缘系统中发生局部放电的部件(匝、相或地绝缘)。该信息可用于通过绝缘系统设计/制造来提高PD起始电压,从而提高电机的可靠性。试验采用4.5 kV可变上升时间浪涌发电机样机进行。对低压交流电机进行测试,以显示商用低压电机中可能发生PD的位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信