{"title":"Passive infrared hyperspectral imaging for standoff detection of tetryl explosive residue on a steel surface","authors":"N. Gallagher, J. Kelly, T. Blake","doi":"10.1109/WHISPERS.2010.5594839","DOIUrl":null,"url":null,"abstract":"A commercial imaging FTIR spectrometer that operates between 850 and 1300 cm−1 was used to passively image a galvanized steel plate stained with a residue of the explosive tetryl (2, 4, 6, N-tetranitro-N-methylaniline). The tetryl was coated onto the plate in a 30 cm diameter spot with an areal dosage of 110 μg tetryl/cm2. The stain on the plate was easily detected at standoff distances of 14 and 31 m by examining the hyperspectral data cubes using maximum autocorrelation factors and a slight modification to a generalized least squares target detection algorithm. End-member extraction showed good comparison in a few key bands between the target end-member and laboratory reflectance spectra; however, significant differences were also observed.","PeriodicalId":193944,"journal":{"name":"2010 2nd Workshop on Hyperspectral Image and Signal Processing: Evolution in Remote Sensing","volume":"23 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 2nd Workshop on Hyperspectral Image and Signal Processing: Evolution in Remote Sensing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WHISPERS.2010.5594839","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
A commercial imaging FTIR spectrometer that operates between 850 and 1300 cm−1 was used to passively image a galvanized steel plate stained with a residue of the explosive tetryl (2, 4, 6, N-tetranitro-N-methylaniline). The tetryl was coated onto the plate in a 30 cm diameter spot with an areal dosage of 110 μg tetryl/cm2. The stain on the plate was easily detected at standoff distances of 14 and 31 m by examining the hyperspectral data cubes using maximum autocorrelation factors and a slight modification to a generalized least squares target detection algorithm. End-member extraction showed good comparison in a few key bands between the target end-member and laboratory reflectance spectra; however, significant differences were also observed.