{"title":"Fault diagnosis of 3/2 connection","authors":"Zhaofei Li, Qing Chen, Zhanjun Gao, Dezhen Nie","doi":"10.1109/ISGT-ASIA.2012.6303352","DOIUrl":null,"url":null,"abstract":"In substations of power system, 3/2 connections are used commonly whose protective relay configurations are complex. There is lots of information when a fault occurs, especially when protective relays and circuit breakers fail to work. How to determine the fault component is particularly intricate. According to above features of 3/2 breaker schemes, this paper put forwards a new fault diagnosis method based on fuzzy Petri nets and associated tree. Markov state-space method is used to calculate the reliability of protective relaying system. This paper defines and corrects the action reality of the main protection, backup protection and breaker failure protection. The concept of group is introduced to define the associated tree, which is used to describe the topology of the 3/2 connection. The associated tree is created to identify every possible fault primary component according to breaker-primary component association. Depending on the relationship of protective relays, a fault diagnosis model based on fuzzy Petri nets is established to determine the faulty components and the fault type quickly and accurately. Finally, by forward and backward reasoning, the malfunctioned circuit breakers and protective relays, even the missing and/or false alarms can be identified. The simulation results given in this paper illustrate that this fault diagnosis method can make a rapid diagnosis and give an accurate evaluation about the 3/2 breaker scheme faults.","PeriodicalId":330758,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2012.6303352","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

In substations of power system, 3/2 connections are used commonly whose protective relay configurations are complex. There is lots of information when a fault occurs, especially when protective relays and circuit breakers fail to work. How to determine the fault component is particularly intricate. According to above features of 3/2 breaker schemes, this paper put forwards a new fault diagnosis method based on fuzzy Petri nets and associated tree. Markov state-space method is used to calculate the reliability of protective relaying system. This paper defines and corrects the action reality of the main protection, backup protection and breaker failure protection. The concept of group is introduced to define the associated tree, which is used to describe the topology of the 3/2 connection. The associated tree is created to identify every possible fault primary component according to breaker-primary component association. Depending on the relationship of protective relays, a fault diagnosis model based on fuzzy Petri nets is established to determine the faulty components and the fault type quickly and accurately. Finally, by forward and backward reasoning, the malfunctioned circuit breakers and protective relays, even the missing and/or false alarms can be identified. The simulation results given in this paper illustrate that this fault diagnosis method can make a rapid diagnosis and give an accurate evaluation about the 3/2 breaker scheme faults.
3/2连接故障诊断
在电力系统变电站中,一般采用3/2接线,其保护继电器配置复杂。当发生故障时,特别是当保护继电器和断路器不工作时,有大量的信息。如何确定故障成分尤其复杂。针对3/2断路器方案的上述特点,本文提出了一种基于模糊Petri网和关联树的故障诊断方法。采用马尔可夫状态空间法计算继电保护系统的可靠性。对主保护、后备保护和断路器失效保护的动作现实进行了界定和修正。引入群的概念来定义关联树,用关联树来描述3/2连接的拓扑结构。根据断路器-主组件的关联关系,创建关联树来识别每个可能的故障主组件。根据继电器之间的相互关系,建立了基于模糊Petri网的故障诊断模型,快速准确地确定了故障部件和故障类型。最后,通过正向和反向推理,可以识别出故障的断路器和保护继电器,甚至缺失和/或误报。仿真结果表明,该故障诊断方法能够对3/2断路器方案的故障进行快速诊断和准确评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信