{"title":"Continuous-time sigma-delta modulator design for wireless biomedical sensing applications","authors":"Yi Yang, Changzhi Li, D. Binkley","doi":"10.1109/WAMICON.2010.5461869","DOIUrl":null,"url":null,"abstract":"This paper discusses the use of continuous-time sigma-delta modulators for ADCs in wireless biomedical sensing applications. The advantages of the proposed continuous-time sigma-delta modulators include the fact that it eliminates the need for an anti-aliasing filter in front of the ADC because of its intrinsic anti-alias filtering property. Additionally, the use of weak inversion and a low flicker noise structure minimizes power consumption and low frequency flicker noise. Finally, the decimation filter used in ordinary sigma-delta ADCs to attenuate high-frequency noise is eliminated because the biomedical sensor analyzes the periodogram in software, thus significantly reducing the cost and power consumption. A design example illustrating these advantages is presented in this paper.","PeriodicalId":112402,"journal":{"name":"2010 IEEE 11th Annual Wireless and Microwave Technology Conference (WAMICON)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE 11th Annual Wireless and Microwave Technology Conference (WAMICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WAMICON.2010.5461869","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
This paper discusses the use of continuous-time sigma-delta modulators for ADCs in wireless biomedical sensing applications. The advantages of the proposed continuous-time sigma-delta modulators include the fact that it eliminates the need for an anti-aliasing filter in front of the ADC because of its intrinsic anti-alias filtering property. Additionally, the use of weak inversion and a low flicker noise structure minimizes power consumption and low frequency flicker noise. Finally, the decimation filter used in ordinary sigma-delta ADCs to attenuate high-frequency noise is eliminated because the biomedical sensor analyzes the periodogram in software, thus significantly reducing the cost and power consumption. A design example illustrating these advantages is presented in this paper.