Mateus Costa Lucena, T. R. Melo, T. Cordeiro, Antônio Marcus Nogueira Lima, Idágene A. Cestari
{"title":"Uma Metodologia Baseada em Modelo para Geração de Opções de Controle do Balão Intra-Aórtico","authors":"Mateus Costa Lucena, T. R. Melo, T. Cordeiro, Antônio Marcus Nogueira Lima, Idágene A. Cestari","doi":"10.17648/sbai-2019-111339","DOIUrl":null,"url":null,"abstract":"The intra-aortic balloon pump (IABP) is a mechanical heart assist device (MHAD), temporally applicable, used to increase blood flow in the arteries of the heart muscle (coronary arteries). The main control problem associated with the BIA is the choice of actuation times that maximize his operational performance. To evaluate the operational reliability of the BIA, control systems check performance indexes. The present work proposes a methodology based on 0D models to generate control recommendations, and also evaluates the association of pulsatility indexes in the quantification of BIA physiological performance. The results obtained suggest that PP, DP and EEP pulsatility indexes can be used to generate control recommendations in accordance with the IABP clinical objectives. Resumo: O balão intra-aórtico (BIA) é um dispositivo mecânico de assistência card́ıaca (DMAC), de aplicabilidade temporária, utilizado para aumentar o fluxo de sangue nas artérias do músculo card́ıaco (artérias coronárias). O principal problema de controle associado ao BIA é a escolha de tempos de atuação que maximizem o desempenho operacional do dispositivo. Para avaliar a corretude operacional do BIA, os sistemas de controle verificam ı́ndices de desempenho. O presente trabalho propõe uma metodologia baseada em modelos 0D para geração de opções de controle, e, avalia ainda, a associação de ı́ndices de pulsatilidade na quantificação de desempenho fisiológico relativa à utilização do BIA. Os resultados obtidos sugerem que os ı́ndices de pulsatilidade PP, DP e EEP podem ser utilizados para gerar opções de controle em compromisso com os objetivos cĺınicos do BIA.","PeriodicalId":130927,"journal":{"name":"Anais do 14º Simpósio Brasileiro de Automação Inteligente","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anais do 14º Simpósio Brasileiro de Automação Inteligente","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17648/sbai-2019-111339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The intra-aortic balloon pump (IABP) is a mechanical heart assist device (MHAD), temporally applicable, used to increase blood flow in the arteries of the heart muscle (coronary arteries). The main control problem associated with the BIA is the choice of actuation times that maximize his operational performance. To evaluate the operational reliability of the BIA, control systems check performance indexes. The present work proposes a methodology based on 0D models to generate control recommendations, and also evaluates the association of pulsatility indexes in the quantification of BIA physiological performance. The results obtained suggest that PP, DP and EEP pulsatility indexes can be used to generate control recommendations in accordance with the IABP clinical objectives. Resumo: O balão intra-aórtico (BIA) é um dispositivo mecânico de assistência card́ıaca (DMAC), de aplicabilidade temporária, utilizado para aumentar o fluxo de sangue nas artérias do músculo card́ıaco (artérias coronárias). O principal problema de controle associado ao BIA é a escolha de tempos de atuação que maximizem o desempenho operacional do dispositivo. Para avaliar a corretude operacional do BIA, os sistemas de controle verificam ı́ndices de desempenho. O presente trabalho propõe uma metodologia baseada em modelos 0D para geração de opções de controle, e, avalia ainda, a associação de ı́ndices de pulsatilidade na quantificação de desempenho fisiológico relativa à utilização do BIA. Os resultados obtidos sugerem que os ı́ndices de pulsatilidade PP, DP e EEP podem ser utilizados para gerar opções de controle em compromisso com os objetivos cĺınicos do BIA.