Yanjie Dai, Zhiru Chen, Xue Zheng, Xianguang Dong, Yan Du, Xiao Liu
{"title":"Smart Electricity Meter Reliability Analysis Based on In-service Data","authors":"Yanjie Dai, Zhiru Chen, Xue Zheng, Xianguang Dong, Yan Du, Xiao Liu","doi":"10.1109/CEEPE51765.2021.9475779","DOIUrl":null,"url":null,"abstract":"Smart electricity meters lifespan is designed more than 10 years, many reliability problems appeared in the operation field, but could not be reproduced in laboratory. We collected field failure records of smart electricity meters installed in two totally different operation environmental conditions, reliability analysis including failure modes, failure rate computation, life statistic, and failure mechanisms were conducted, and then the results were compared to the prediction results according to IEC 62380. Some existing problems were pointed out and some advices were proposed in order to improve the reliability of smart electricity meters.","PeriodicalId":308213,"journal":{"name":"2021 4th International Conference on Energy, Electrical and Power Engineering (CEEPE)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 4th International Conference on Energy, Electrical and Power Engineering (CEEPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEPE51765.2021.9475779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Smart electricity meters lifespan is designed more than 10 years, many reliability problems appeared in the operation field, but could not be reproduced in laboratory. We collected field failure records of smart electricity meters installed in two totally different operation environmental conditions, reliability analysis including failure modes, failure rate computation, life statistic, and failure mechanisms were conducted, and then the results were compared to the prediction results according to IEC 62380. Some existing problems were pointed out and some advices were proposed in order to improve the reliability of smart electricity meters.