Miniature EMG Sensors for Prosthetic Applications

A. Marinelli, N. Boccardo, M. Semprini, A. Succi, M. Canepa, Samuel Stedman, L. Lombardi, Alberto Dellacasa Bellingegni, M. Chiappalone, E. Gruppioni, M. Laffranchi, L. Michieli
{"title":"Miniature EMG Sensors for Prosthetic Applications","authors":"A. Marinelli, N. Boccardo, M. Semprini, A. Succi, M. Canepa, Samuel Stedman, L. Lombardi, Alberto Dellacasa Bellingegni, M. Chiappalone, E. Gruppioni, M. Laffranchi, L. Michieli","doi":"10.1109/NER49283.2021.9441111","DOIUrl":null,"url":null,"abstract":"Poly-articulated, myoelectric hand prostheses reproduce complex multi-degree of freedom movements. Typically, a pattern recognition algorithm translates the recorded electromyographic (EMG) activity into joint movements. Control algorithms may benefit by adding more EMG sensors, however, their mechanical integration within the socket strongly affects the physical robustness of the prosthetic system. Their typical size and rectangular shape are indeed nonoptimal for the limited amount of space within the socket. To solve this issue, here we present and test custom-made sensors for decoding multi-joint hand movements from EMG recordings of arm muscles. The sensors have circular shape and smaller size with respect to their standard counterpart, thus allowing a higher number of channels for multi-DOF control strategies. In order to evaluate their performance for multi-joint decoding, we tested a Non-Linear Logistic Regression classifier on both healthy and amputated subjects. We optimized the classifier in terms of F1Score, depending on the number of EMG sensors, and in terms of Embedding Optimization Factor, depending on the polynomial complexity degree. We then compared performance with that of standard rectangular EMG sensors and found no significant difference. Our custom-made sensors achieved higher F1Score for all the patients. This result, coupled with more effective integration with the socket, suggests effective prosthetic applications for our sensors.","PeriodicalId":413977,"journal":{"name":"2021 10th International IEEE/EMBS Conference on Neural Engineering (NER)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 10th International IEEE/EMBS Conference on Neural Engineering (NER)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NER49283.2021.9441111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Poly-articulated, myoelectric hand prostheses reproduce complex multi-degree of freedom movements. Typically, a pattern recognition algorithm translates the recorded electromyographic (EMG) activity into joint movements. Control algorithms may benefit by adding more EMG sensors, however, their mechanical integration within the socket strongly affects the physical robustness of the prosthetic system. Their typical size and rectangular shape are indeed nonoptimal for the limited amount of space within the socket. To solve this issue, here we present and test custom-made sensors for decoding multi-joint hand movements from EMG recordings of arm muscles. The sensors have circular shape and smaller size with respect to their standard counterpart, thus allowing a higher number of channels for multi-DOF control strategies. In order to evaluate their performance for multi-joint decoding, we tested a Non-Linear Logistic Regression classifier on both healthy and amputated subjects. We optimized the classifier in terms of F1Score, depending on the number of EMG sensors, and in terms of Embedding Optimization Factor, depending on the polynomial complexity degree. We then compared performance with that of standard rectangular EMG sensors and found no significant difference. Our custom-made sensors achieved higher F1Score for all the patients. This result, coupled with more effective integration with the socket, suggests effective prosthetic applications for our sensors.
用于假肢的微型肌电传感器
多关节,肌电手假体再现复杂的多自由度运动。通常,模式识别算法将记录的肌电图(EMG)活动转换为关节运动。通过增加更多的肌电传感器,控制算法可能会受益,然而,它们在插座内的机械集成强烈影响假肢系统的物理稳健性。它们的典型尺寸和矩形形状对于插座内有限的空间来说确实不是最佳的。为了解决这个问题,我们提出并测试了定制的传感器,用于从手臂肌肉的肌电图记录中解码多关节手部运动。该传感器具有圆形和较小的尺寸相对于他们的标准对应物,从而允许更多的通道多自由度控制策略。为了评估它们对多关节解码的性能,我们在健康和截肢受试者上测试了非线性逻辑回归分类器。我们根据EMG传感器的数量,根据F1Score对分类器进行优化,根据多项式的复杂度,根据Embedding Optimization Factor对分类器进行优化。然后,我们将其性能与标准矩形肌电传感器进行了比较,发现没有显著差异。我们定制的传感器对所有患者都达到了更高的F1Score。这一结果,加上与插座更有效的集成,为我们的传感器提供了有效的假肢应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书