Investigating Power Line Termination Device Effectiveness in Regards to Radiated Emission Measurement Reproducibility in Consideration of Two Disturbance Sources and AC Mains Cable

S. Okuyama, K. Osabe, N. Kuwabara, F. Amemiya, T. Shimasaki, H. Muramatsu
{"title":"Investigating Power Line Termination Device Effectiveness in Regards to Radiated Emission Measurement Reproducibility in Consideration of Two Disturbance Sources and AC Mains Cable","authors":"S. Okuyama, K. Osabe, N. Kuwabara, F. Amemiya, T. Shimasaki, H. Muramatsu","doi":"10.1109/EMCEUROPE48519.2020.9245734","DOIUrl":null,"url":null,"abstract":"Reproducibility of radiated disturbance measurements is influenced by the line impedance of the power source used for EUT. A VHF-LISN was proposed to solve this issue. A VHF-LISN can define line impedance so as to avoid such influences caused by different line impedances for connection points at different test sites. At present, two proposed types of VHF-LISN - balanced termination and unbalanced termination - are being considered for implementation in CISPR 16 basic measurement standards. Round robin testing was conducted to investigate the effectiveness of improving reproducibility of radiated emission measurement with two types of VHF-LISN, using a versatile comb generator having two signal source modes, common mode (CM) and differential mode (DM), and by using both 2-wire and 3-wire AC mains cable respectively. CMAD termination was provided as an option. The testing concluded that reproducibility between test sites was improved by VHF-LISN termination for both CM and DM emission sources with CMAD termination effectiveness proving to be limited in the case of 2-wire mains cable being used in CM signal source measurements.","PeriodicalId":332251,"journal":{"name":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","volume":"103 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE48519.2020.9245734","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Reproducibility of radiated disturbance measurements is influenced by the line impedance of the power source used for EUT. A VHF-LISN was proposed to solve this issue. A VHF-LISN can define line impedance so as to avoid such influences caused by different line impedances for connection points at different test sites. At present, two proposed types of VHF-LISN - balanced termination and unbalanced termination - are being considered for implementation in CISPR 16 basic measurement standards. Round robin testing was conducted to investigate the effectiveness of improving reproducibility of radiated emission measurement with two types of VHF-LISN, using a versatile comb generator having two signal source modes, common mode (CM) and differential mode (DM), and by using both 2-wire and 3-wire AC mains cable respectively. CMAD termination was provided as an option. The testing concluded that reproducibility between test sites was improved by VHF-LISN termination for both CM and DM emission sources with CMAD termination effectiveness proving to be limited in the case of 2-wire mains cable being used in CM signal source measurements.
考虑两个干扰源和交流市电电缆辐射发射测量再现性的电力线终端装置有效性研究
辐射扰动测量的再现性受到用于EUT的电源的线阻抗的影响。为了解决这个问题,VHF-LISN被提出。VHF-LISN可以定义线路阻抗,以避免不同测试点的连接点线路阻抗不同所造成的影响。目前,两种被提议的VHF-LISN——平衡终端和不平衡终端——正在考虑在CISPR 16基本测量标准中实施。采用具有共模(CM)和差模(DM)两种信号源模式的通用梳状发生器,并分别使用2线和3线交流主电缆,进行了轮询测试,以研究两种VHF-LISN提高辐射发射测量再现性的有效性。CMAD终止是一种选择。测试结果表明,对于CM和DM信号源,VHF-LISN终端提高了测试点之间的再现性,而在CM信号源测量中使用2线主电缆的情况下,CMAD终端的有效性被证明是有限的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信