R. Baharom, M. N. Seroji, M. Salleh, K. S. Muhammad
{"title":"Impact of switching frequency variation to the power transfer efficiency of wireless power transfer converter","authors":"R. Baharom, M. N. Seroji, M. Salleh, K. S. Muhammad","doi":"10.1109/ISCAIE.2016.7575050","DOIUrl":null,"url":null,"abstract":"This paper presents the impact of the switching frequency variation to the power transfer efficiency of a wireless power transfer converter. An experimental demonstrator is used to as a model for this study. The transmitter use Wurth Elektronik wireless power charging coils, 24μH, 10%, which is installed across the output of high frequency half-bridge inverter. The switching frequency is varied from 10kHz in steps of 10kHz until 100kHz. The distance between the coils is fixed at 10mm. The receiving coil is fed with a high frequency full-bridge rectifier and a DC load. Experimental results show that the power transfer efficiency varies when the switching frequency is increased. The power transfer efficiency reached its peak at 72% when the switching frequency is at 30kHz.","PeriodicalId":412517,"journal":{"name":"2016 IEEE Symposium on Computer Applications & Industrial Electronics (ISCAIE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Symposium on Computer Applications & Industrial Electronics (ISCAIE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISCAIE.2016.7575050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
This paper presents the impact of the switching frequency variation to the power transfer efficiency of a wireless power transfer converter. An experimental demonstrator is used to as a model for this study. The transmitter use Wurth Elektronik wireless power charging coils, 24μH, 10%, which is installed across the output of high frequency half-bridge inverter. The switching frequency is varied from 10kHz in steps of 10kHz until 100kHz. The distance between the coils is fixed at 10mm. The receiving coil is fed with a high frequency full-bridge rectifier and a DC load. Experimental results show that the power transfer efficiency varies when the switching frequency is increased. The power transfer efficiency reached its peak at 72% when the switching frequency is at 30kHz.