Synchrophasor time skew: Formulation, detection and correction

Qiang Zhang, V. Venkatasubramanian
{"title":"Synchrophasor time skew: Formulation, detection and correction","authors":"Qiang Zhang, V. Venkatasubramanian","doi":"10.1109/NAPS.2014.6965457","DOIUrl":null,"url":null,"abstract":"The most critical part of the synchrophasor technology is the availability of accurate UTC time. Usually an external GPS clock device feeds PMU with 1 pulse per second time signals. During the second, PMU's internal clock keeps the pace until the next time signal arrives. Because of various reasons, time skews have been observed in some real life synchrophasor data. Two fundamental types of time skews are identified in this paper. Synchrophasor time skew problem is fundamentally different from that in SCADA system, because time shift is translated into error in phase angle measurements and subsequent errors in frequency and rate of change of frequency measurements. Algorithms are developed to automatically detect time skews online and to estimate the time errors. A correction method is also provided. Both simulated data and real life data are used to verify that the proposed methods are effective and accurate.","PeriodicalId":421766,"journal":{"name":"2014 North American Power Symposium (NAPS)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2014.6965457","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

The most critical part of the synchrophasor technology is the availability of accurate UTC time. Usually an external GPS clock device feeds PMU with 1 pulse per second time signals. During the second, PMU's internal clock keeps the pace until the next time signal arrives. Because of various reasons, time skews have been observed in some real life synchrophasor data. Two fundamental types of time skews are identified in this paper. Synchrophasor time skew problem is fundamentally different from that in SCADA system, because time shift is translated into error in phase angle measurements and subsequent errors in frequency and rate of change of frequency measurements. Algorithms are developed to automatically detect time skews online and to estimate the time errors. A correction method is also provided. Both simulated data and real life data are used to verify that the proposed methods are effective and accurate.
同步时间偏差:制定、检测和校正
同步相量技术最关键的部分是提供准确的UTC时间。通常,外部GPS时钟设备以每秒1脉冲的时间信号馈送PMU。在第二次,PMU的内部时钟保持步调,直到下一个时间信号到达。由于各种原因,在一些现实生活中的同步数据中观察到时间偏差。本文确定了两种基本类型的时间偏差。同步相量时偏问题与SCADA系统中的时偏问题有着本质的区别,因为时偏会转化为相角测量的误差以及随后频率和频率变化率测量的误差。开发了在线自动检测时间偏差和估计时间误差的算法。还提供了一种校正方法。仿真数据和实际数据验证了所提方法的有效性和准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信